A. RELAY ACTIVATION TIMES
Set the amount of time the gate/relay will remain activated. The default setting is 10 seconds and the valid time
range for activation is 2-255 seconds.
Format:
Note:
B. NUMBER OF DIGITS IN ENTRY CODES
If you decide to change the number of digits in the entry codes after the initial programming, you will need to
delete all of the entry codes before changing the code length (see section 7.C). Once the change in code length
has been made, the old codes will no longer be valid and cannot be
codes and the valid range is 4 or 5 digits
Format
Example
C. STRIKES-AND-OUT
Set how many incorrect entry codes may be entered within a 3 minute period before the system deactivates for a
period of 3 minutes. The "strike count" will be cleared when either a valid entry code is entered or if the keypad
has not had any input for 60 seconds since the last keystroke. When the "strike count" has been reached, all
keypad input will be ignored, including access to the programming mode.
Format
Example
Notes
D. CHANGE THE PASSWORD
Ensure that the password required to enter the programming mode is known only by authorized personnel. Make
sure to write down the new password so you can re-enter programming at a later date.
Format
Example
E. VERIFY THE PASSWORD
Verify the password entry to ensure proper setting. If the password entered is correct, two short beeps will be
emitted from the system. If it is the incorrect code, the system will emit one long beep.
If the unit responds with an error tone, do not exit programming. The number that you entered does not match
the password. Repeat steps D and E for proper password setting
Format
INITIAL SYSTEM SETUP
1 + no. of seconds + #
2 + no. of seconds + #
If this relay activates a gate operator with a momentary contact closure, set the relay activation
time for a short period (for example, 2 seconds). A longer activation time might cause the gate to
repeatedly open and close until the activation period has expired.
8 + number of digits (1 digit) + #
8 + 5 + # (sets the number of digits in entry codes to 5)
.
3 + number of incorrect codes (up to 2 digits) + #
3 + 3 + # (sets strikes-and-out to 3).
Valid range is 0 to 10.
Default setting is 5.
To disable the strikes-and-out enter zero (0).
9 + password (6 digits) + #
9 + 123456 + #
(If the unit responds with two short beeps, the number that you entered was accepted)
4 + password (6 digits) + #
SECTION 2
Main Relay
Auxiliary Relay
Doc 6001050, Rev C
Page 4 of 5
erased.
Default setting is for 4-digit entry