Minimum Wall and Ceiling Clearances
This fireplace can be installed with zero (0") clearance to
combustible material.
When facing the front of the appliance the minimum clearances to
combustible construction (material) are the following:
1. Clearances from the right side or left side of the fireplace
opening to any combustible wall or material should not be
less than 4 inches.
2. Clearances from the top of the fireplace opening to the ceiling
should not be less than 30 inches.
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard.
24161-0-1207
CLEARANCES
30"
(762mm)
Figure 4
COMBUSTIBLE MATERIAL
Figure 6
Mantel Clearances for Built-in Installation
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.
Figure 5
Figure 7
Page 9