Download Print this page

Kenwood KDC-2031SA Service Manual page 9

Cd receiver
Hide thumbs Also See for KDC-2031SA:

Advertisement

QQ
3 7 63 1515 0
How to enter the test mode
While simultaneously press PRESET "1" key and PRESET "3"
key, press "RESET" button.
How to release the test mode
Press "RESET" button. (The release cannot be achieved in
the conditions of POWER OFF and ACC OFF.)
Initial conditions of the test mode
• The source is "STANDBY".
• The displays all lit up.
• The volume is at –10dB (The display shows "30".)
• LOUD is "OFF".
• SYSTEM Q is "NATURAL".
• BEEP is sounded at all time with the key depressed for less
than 1 second.
Special displays when all indicator lights are lighted
When "PRESET" keys are pressed while all indicators for the
STANDBY sources are lighted, the following displays will ap-
pear.
TE
L 13942296513
PRESET • Version display (4 digits : month, date)
"1" key
(4digits : hour, minute)
(Display) : XXXX xxxx
PRESET • Serial number display (4 digits) (4 digits)
"2" key
(Display) : XXXX xxxx
PRESET • When pressed for less than 1 second : POWER ON
"3" key
time display (STANDBY source time is not counted.)
(Display) : _ _ _ X xxxx
* The display is cleared by pressing the key for more
than 2 seconds.
PRESET • When pressed for less than 1 second : CD operation
"4" key
time display
(Display) : _ _ _ X xxxx
* The display is cleared by pressing the key for more
than 2 seconds.
www
.
TEST MODE
MAX 60,000 (hours)
MAX 60,000 (hours)
x
ao
u163
y
i
2 9
8
PRESET • When pressed for less than 1 second : CD EJECT
"5" key
number display
(Display) : _ _ _ X xxxx
* The display is cleared by pressing the key for more
than 2 seconds.
PRESET • When pressed for less than 1 second : Panel open/
"6" key
close number display
(Display) : _ _ _ X xxxx
* The display is cleared by pressing the key for more
than 2 seconds.
"FM"
• ROM CORRECTION version display
key
(Display)
Effective : Rxxx (x : number)
Not effective (When not able to read) : R – – –
Not effective (When version is different) : R
"AM"
• IC10 adjustment status (Refer to "ADJUSTMENT" on
key
the following page.)
(Display)
Q Q
Adjustment complete : E2OK
3
6 7
1 3
1 5
Adjustment not completed : E2ER
Communication error : ICER
* When other than "E2P _ OK _ _" , Pin No. 30 will
become "H".
"
"
• Mechanism error detection status
• Communication error → Error No. 1 → Error No. 2 →
key
Error No. 3 → Communication error (Error No. 1 is the
most recent error.)
(Display)
Communication OK : ICOK
Communication error : ICER
Not detected : En – – (n : 1~3)
Detected : En
* The display is cleared by pressing the key for more
than 2 seconds.
co
.
KDC-2031SA/2031SAY
KDC-2031SG/2031SGY
9 4
2 8
MAX 60,000 (times)
MAX 600,000 (times)
0 5
8
2 9
9 4
2 8
(
: error code)
m
9 9
9 9
9

Advertisement