Sanyo PLC-HP7000L Service Manual page 49

Multimedia projector
Hide thumbs Also See for PLC-HP7000L:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No. Item
22
Alpha BB Green
23
Alpha BB Blue
80
FINE FPGA-Setting
0
UV DLT
1
UV Gain
2
UV SFT
3
Demo On/Off
4
Demo Mode
5
Area Big Chg
6
Area Small Chg
7
Area Chg Sens
8
Show Mode
9
AI_Calc_Mode
230
DATA_SHIFT
232
DOT_CKSW
81
FINE FPGA-Color Management
0
YRange
1
HueRange
2
GainRange
3
GM_MinSlope
4
GM_MaxSlope
5
GM_Converge
6
Not used
7
Not used
8
COLM_GET_KIND_Y_ud
9
Not used
10
Not used
11
SameHue
12
Cut_UVNorm
13
Cur_MinY
14
Cur_MaxY
15
Same_Y
16
Conv_Y
17
WB_Limit 0
18
WB_Limit 1
19
WB_Limit 2
20
WB_Limit 3
21
WB_Limit 4
22
WB_Limit 8
23
WB_Limit In
24
WB_Limit Out
25
WB_Limit PtFlg
82
FPGA - Ye Overlay
0
DEC_R
1
DEC_G
2
B_RATIO
3
SAT_SLOPE
4
R_SLOPE
5
G_SLOPE
6
LUM_MAX
7
LUM_MAX
8
LUM_MAX
9
LUM_MAX
10
LUM_MAX
11
LUM_MAX
12
LUM_MAX
13
LUM_MIN
14
LUM_MIN
15
LUM_MIN
16
LUM_MIN
17
LUM_MIN
18
LUM_MIN
19
LUM_MIN
20
YE_SENS
21
YE_TESTFLG
22
DAC_MAX
23
DAC_MIN
Function
Dem mode On/Off 1: Display, 0: No display
Mode 0: Demo0, 1: Demo1
Area Id
Area Id
Area Id
Test Mode 0: Normal, 1: SHW1, 2:SHW2, 3:Test
AI Calcuration
Gamma Mini Slope x 100
Gamma Max Slope x 10
Gamma Converge x 10
No. of Acquire Points
Ye Overlay Control: R Coefficient(-)
Ye Overlay Control: G Coefficient(-)
Ye Overlay Control: B Coefficient(+)
Ye Overlay Control: Coefficient(Saturation)
Ye Overlay Control: Coefficient(R-tint)
Ye Overlay Control: Coefficient(G-tint)
Ye Overlay Control: Coefficient(Max) PC-Dynamic
Ye Overlay Control: Coefficient(Max) PC-Standard
Ye Overlay Control: Coefficient(Max) PC-Real
Ye Overlay Control: Coefficient(Max) AV-Dynamic
Ye Overlay Control: Coefficient(Max) AV-Standard
Ye Overlay Control: Coefficient(Max) AV-Natural
Ye Overlay Control: Coefficient(Max) AV-Cinema
Ye Overlay Control: Coefficient(Min) PC-Dynamic
Ye Overlay Control: Coefficient(Min) PC-Standard
Ye Overlay Control: Coefficient(Min) PC-Real
Ye Overlay Control: Coefficient(Min) AV-Dynamic
Ye Overlay Control: Coefficient(Min) AV-Standard
Ye Overlay Control: Coefficient(Min) AV-Natural
Ye Overlay Control: Coefficient(Min) AV-Cinema
Ye Overlay Control: Time Constant
Ye Overlay Control: Test Flag
Not used
Not used
Range
0 - 1000
20/20/20/20/20/20/ 20/20/20/20/20
0 - 1000
20/20/20/20/20/20/ 20/20/20/20/20
0 - 31
0 - 2047
0 - 32767
0 - 1
0 - 7
0 - 4095
0 - 4095
0 - 4095
0 - 3
0 - 2
0 - 7
0 - 1
0 - 32
0 - 20
0 - 50
0 - 10
10 - 30
1 - 5
1 - 9
1 - 10
0 - 64
0 - 127
128 - 255
0 - 63
0 - 127
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 1
TYPE-L
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
-49-
Initial
Note
3
1030
6180
0
0
67
67
150
0
2
4
0
8
10
30
3
18
3
9
3
5
0
255
24
64
4
40
41
41
41
41
14
20
1
TYPE-R
Panel Type
130
170
* The value is initial-
30
10
ized when the panel
type is switched.
15
15
71
16
16
255
255
255
255
255
255
255
255
255
255
255
255
255
255
0
0
0
0
0
0
0
0
0
0
0
0
0
0
4
3
255
0

Advertisement

Table of Contents
loading

Table of Contents