  • Page 1 INSTALLATION MANUAL...
  • Page 2 Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 3: Safety Warnings

    Before connecting the equipment, observe the safety warnings section and ensure that the local mains supply is within the rating stated on the rear of the equipment. The HD1012 systems have power supplies that are suitable for voltages of 115V (+6% -10%) and 230V (+/-10%) @ 50 and 60Hz.
  • Page 4 Empty Holder - There is an empty battery holder on the MBX card in the Control Panel, this holder is not used. No battery should be fitted to this card! Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 5 This equipment complies with the following standards: BS EN60950 (2000) Safety of information Technology Equipment Including Electrical Business Equipment. UL1419 (1997) Standard for Safety – Professional Video and Audio equipment, S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page v...
  • Page 6 D-type connectors shall have metal shells making good RF contact with the cable screen. Connectors having "dimples" which improve the contact between the plug and socket shells, are recommended. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 7: Table Of Contents

    Mainframe RS-232 ......................34 GPIs & GPOs ........................35 Control Panel to LCD ......................36 SYSTEM WITH INTEGRATED ROUTER ..................38 SECTION B - SPECIFICATIONS ..................41 S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page vii...
  • Page 8 Router Protocols ..................……… 21 GPI Function Mapping..................24 Mainframe RS-232/422 Connector Pinouts............34 GPI/P Connector Pinout ................…….. 35 Control Panel to LCD Wiring ................36 Page viii HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 9: Section A - Installation

    SECTION A INSTALLATION S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 1...
  • Page 10: Introduction

    INTRODUCTION These installation instructions provide a guide to the installation of the HD1012 High-Definition Switchers. ON DELIVERY OF THE SYSTEM The equipment is supplied in dedicated packaging provided by the manufacturer and should not be accepted if delivered in inferior or unauthorised materials.
  • Page 11: Location And Environment

    There is a battery holder on the MBX card within the Control Panel which is not used. No battery should be fitted to this card S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 3...
  • Page 12: Power Supplies

    The mainframe is protected by an internal fuse that is not user replaceable. E = Protective Earth Conductor N = Earthed Neutral Conductor L = Phase Conductor Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 13: System Interconnection

    The HD1000 mainframe has a shutdown switch for each power supply behind the front door on the left hand side. When the power supply is shut down, the red light in the shutdown button will illuminate. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 5...
  • Page 14: Button Bus Multi Control

    T-bar movements will control both mainframes simultaneously. Note Button Bus Multi Control is an option that requires an enabling password. A password is available from Snell & Wilcox technical support. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 15: Control Panel - Rear View

    S NELL & WILCOX SE RIAL No. MADE IN SAFFRO N WALDEN, ESSEX, UK. 250V Control Panel - Rear View Control Panels’ Top Connector Plate S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 7...
  • Page 16: Control Panel Dimensions

    SYSTEM INTERCONNECTION - continued CP1512 Dimensions in mm Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 17: Switcher Mainframe Rear Panel

    SYSTEM INTERCONNECTION - continued HD1000 Switcher Mainframe - Rear Panel & Connectors S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 9...
  • Page 18: Inputs

    HD1000 Mainframe Inputs Program Clean Clean Program Preview 1 Pvw-1 Preview 2 Pvw-2 Analogue Preview Aux 1 Aux 2 Aux 3 Aux 4 Loop Terminator Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 19: Muliple Monitor Mode

    Preview 1 are limited to the P/P & DSK signals and the signal on Preview 2 is forced to M/E Pvw. I.e., the Preview 2 selection buttons do not function. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 11...
  • Page 20: Referencing

    60Hz 74.25MHz 1650 (1280) 79.43 lines; 1.765ms 22.22µs 720p 59.94Hz 1650 (1280) 74.25/1.001MHz 79.43 lines; 1.767ms 22.24µs Figures in the right-hand two columns are approximate. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 21: Referencing - System Delays

    Ref Sync Output’s Sync H/V-Phase controls may need to be adjusted. Any signals sent through a DVE will be delayed by precisely one extra frame. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 13...
  • Page 22: Control Ports And Protocols

    GVG 100 This editor protocol allows control from an editor capable of driving a GVG100 or 110 switcher. The main portion of the interface is mapped onto the HD1012’s main mixing bus. The DSK and Fade-to-Black sections are also driven.
  • Page 23: Gvg 4000

    Wipe numbers 100 to 103 trigger the following functions: 100 - Non Additive Mix. 101 - SUPERmix. 102 - DVE BacKGrounD transition. 103 - All enabled TIMELINEs. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 15...
  • Page 24: Sony Dvs

    Wipe numbers 100 to 103 trigger the following functions: 100 - Non Additive Mix. 101 - SUPERmix. 102 - DVE BacKGrounD transition. 103 - All enabled TIMELINEs. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 25: Sony Dvs Crosspoints

    Still 3 (all but HD AUX busses) Chromakey Fill 1 Still 4 (all but HD AUX busses) Chromakey Fill 2 Chromakey Source 1 Chromakey Source 2 S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 17...
  • Page 26: Using A Sony Bve-9100 Editor

    The problem is easily overcome by a setting on the editor. If, when running the HD1012 switcher from a Sony BVE-9100 editor, the edit timing appears to be inaccurate, please follow this procedure.
  • Page 27 00 to 02 inclusive with GVG-100 protocol: 00 approx. Therefore a setting of 02 allows both Sony BVS/DVS and GVG-4000 protocols to be used without further adjustment. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 19...
  • Page 28: Vtr

    The left-hand two connectors form a transparent loop-through between the editor and the VTR, and can be connected either way round. The right-hand connector should be plugged into a cable leading to the switcher. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 29: S & W Tally

    N / A Pre PESA Rtr PESA Cougar HD N / A Pre PESA Rtr NVision HD series N / A Pre NVision Rtr S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 21...
  • Page 30: General Purpose Inputs & Outputs

    D-type) on the rear of the mainframe. The second eight are on the GPI & Tally connector (25 way D-type) on the rear of the Quad DSK unit. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 31: The Outputs

    Triggers fired from a Skateboard or via a Key Macro. Note A complete list of all of the “occurrences” which may be tallied on the General Purpose Outputs (GPO) is on page 27. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 23...
  • Page 32: Programming The Inputs

    GPI. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 33: Programming The Outputs

    Active State The active state of the output relay may be set as “Closed” or “Open” by F5R (Relay) which toggles between open and closed. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 25...
  • Page 34: Multiple Conditions

    With three conditions there are four available states they are: [C1 and C2 and C3], [C1 or C2 or C3], [(C1 and C2) or C3] or [(C1 or C2) and C3]. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 35: List Of Gpo Occurences

    Key Action Skateboard Triggers 1 to 8. These may be directly fired from a Skateboard button or set as part of a Key Macro. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 27...
  • Page 36: Other Installation Procedures

    They will then all extinguish and the system will reboot. No stored data (DMEMs, stills, configs, etc.) will be lost as a result of this process. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 37: Remote Allocation Of Aux Sources

    Switcher set-up for Pro-Bel panels The switcher serial port to which the panel is connected must be set to “Aux Ctrl ProBel” S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 29...
  • Page 38: Quartz Panel Button Functions

    Up to eight panels connected to one switcher mainframe port to control all available Aux outputs on a one panel per Aux output. This method requires some simple interface equipment being made, see below. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 39 The male 9 way “D”- type connects to the switcher port and the control panels connect to the female connectors via the Diode Buffers which are detailed below . S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 31...
  • Page 40: Diode Buffer

    RX - Pin 9 Pin 9 Both diodes are 1N4148 and both resistors are 100 ohm. The resistors are only fitted to the master diode buffer. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 41: Aux Control Interconnections

    Master Diode Buffer is used Switcher for one of them and that it is located at the Mainframe end of the Extender Cable S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 33...
  • Page 42: Connector Pinouts

    As can be seen from the above, the HD1000 Mainframe is configured as a DCE (not DTE) RS-232 device, therefore only a pin-to-pin cable is required to connect this port to a PC. This configuration is permanently fixed. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 43: Gpis & Gpos

    There are eight GPI inputs which form GPIs 9 to 16 in the switcher GPI menu. The pinouts on the 25way D-type GPI & TALLY connector are given below. Common S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 35...
  • Page 44: Control Panel To Lcd

    Pin 13 Green Pin 3 Pair 6 Pin 14 Black Pin 4 The cable used has six twisted-pairs of 7/0.2mm wire and an overall shield. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 45 Brown-Black Pin 41 P12V_LCD +12V_PSU Pin 43 White-Brown Pin 43 P12V_LCD The cable used has thirty-six cores of 7/0.2mm wire and an overall shield. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 37...
  • Page 46: System With Integrated Router

    SYSTEM WITH INTEGRATED ROUTER An integrated router may by used with the HD1012 system to increase the number of available sources. This router may be the Snell & Wilcox HD1132 or a supported third party router. When using an integrated router the switcher mainframe inputs become bus inputs rather than source inputs.
  • Page 47: Integrated Router Connections

    An offset may be set to move the outputs being used with the switcher to a contiguous block of 20 starting at a number other than 1. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 39...
  • Page 48 DELIBERATELY BLANK Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 49: Section B - Specifications

    SECTION B SPECIFICATIONS S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 41...
  • Page 50 Input synchronisers on all paths. Range: 131072 x 74.25MHz or 74.25/1.001MHz clock Synchronisation periods (= ~1.76ms). This is equal to between about 47.66 and 79.43 lines, depending upon line-standard. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 51 Analogue HD Reference ±300mV tri-level sync. 300mV sync with optional 300mV pk-pk burst ? 6dB Analogue SD Reference Impedance: 75 ohms (except reference input). S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 43...
  • Page 52 700mV black-white with ±300mV tri-level sync. 700mV pk-pk for 100% bars with ±300mV tri-level Analogue Pb / Pr sync. Analogue Reference ±300mV tri-level sync. (HD only) Output Impedance: 75 ohms Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 53 32 isolated contact closures on 2½ x 25-way female Tally outputs D-type. RollCall™ Arcnet on 1 x BNC. Diagnostics RS-232 (DCE) on 1 x 9-way female D-type. S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 45...
  • Page 54 RS-232 (DCE) on 1 x 9-way female D-type. (Later Mark 2 Panels) CONTROL INTERFACES - Control Panel Built-In Display 1 x 25-way female D-type. Control Panel 1 x 9-way female D-type. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 55 871mm x 537mm (not including display overhang) 819mm x 511.5mm Suggested Cutout 822mm x 517mm Depth Clearance 200mm Weight To be advised. 5 to 35 ?C non-condensing. Environmental S&W Production & Post Production HD1012 Installation Manual – V3, Issue 1, Rev 1 Page 47...
  • Page 56 2 x IEC socket. POWER REQUIREMENTS Voltage 115V/230V @ 50/60Hz Mainframe Power Less than 1000 Watts with all options fitted. Control Panel Power Less than 50 Watts. Page HD1012 Installation Manual – V3, Issue 1, Rev 1 S&W Production & Post Production...
  • Page 57 www.snellwilcox.com END OF MANUAL S&W Production & Post Production...