Specifications - Rockford Fosgate RFC10HB Installation & Operation Manual

10 farad hybrid capacitor
Table of Contents

Advertisement

I
NSTALLATION
DISPOSING OF HYBRID CAPACITOR CELLS
A Rockford Hybrid Capacitor cell contains hazardous material, such as Acetonitrile (ACN).You must
follow federal, state, and local laws when disposing of failed or aged cells. For more information, contact
the Customer Support department of Rockford Corp. 1-800-669-9899. Capacitor modules that have
reached their end-of-life can be recycled. Rockford Corp. will take back capacitor modules that need to
be recycled. Rockford does not pay for shipping of returned capacitor modules that are to be recycled.
CAUTION: To prevent injury due to hazardous chemicals, do not touch the capacitor if
the safety vent has ruptured. Have the system looked at
by a qualified technician for repair and/or disposal.
S
PECIFICATIONS
MODEL- 10 Farad Hybrid Capacitor
Rated Capacitance – 77°F (25°C)
(Constant Current Discharge (5A) 15.0v–>3.0v)
Capacitance Tolerance
Rated Voltage,VR
Surge Voltage
Maximum Internal Resistance (ESR):
Operating Temperature Range*
Storage Temperature Range
Input/Output Connections
(AWG-American Wire Gauge)
Dimensions:
Height
Width
Length
Weight:
*Prolonged operation above the operating temperature limit of a cell will greatly reduce its useful life
span. Exposure to temperatures below the operating temperature will reduce the ability of the cell to
easily accept a charge.
8
Specifications subject to change without notice
RFC10HB
10 Farad
±10%
16.0 Volts
18.0 Volts
<6.5m
-40 to 140°F
(-40 to 60°C)
-40 to 158°F
(-40 to 70°C)
(6) 1/0 AWG and/or 4 AWG
2.25" (5.72cm)
10.25" (26.04cm)
6.5" (16.51cm)
3.31 lbs. (1.5kg)

Hide quick links: