Download Print this page

ABS ABT-RFC-7P Owner's Manual

Pharmacy refrigerator and freezer combination

Advertisement

Part number 20068, Rev 0
Pharmacy Refrigerator and Freezer Combination
This manual describes how to operate and care for your appliance to get the best, most efficient, performance.
Note to Customer:
This merchandise was carefully packed and thoroughly inspected before leaving our plant. Responsibility for its
safe delivery was assumed by the carrier upon acceptance of the shipment. As directed on the side of your
packing carton, claims for loss or damage sustained in transit must be made on the carrier as follows:
A.) Visible Loss, Damage, Shortage External Evidence of Loss or Damage: This type of damage must be noted on
the freight bill and acknowledged by the carrier's agent (driver) at time of delivery. Make sure you get a signed
copy. Send a written request for an inspection to the carrier.
B.) Concealed Damage: This type of damage may not be discovered until the unit is being unpacked. When
concealed damage is discovered, stop unpacking immediately and contact the carrier immediately to report
the claim and request an inspection. This should be done as soon as possible and, in any case, must be done
within 15 days or receiving the merchandise. If at all possible, do not move the item and save all packaging
material for carrier's inspection.
C.) FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN THE CARRIER REFUSING TO HONOR YOUR
COMPANY'S CLAIM. UNDER NO CIRCUMSTANCES SHOULD THE MERCHANDISE BE RETURNED TO THE
MANUFACTURER. NO RETURNS WILL BE ACCEPTED WITHOUT PRIOR AUTHORIZATION.
Horizon Scientific
125 Varnfield Drive
Summerville, SC 29483
Phone: 800-648-4041
Fax:
843-821-8051
ABT-RFC-7P
OWNER'S INSTRUCTIONS
READ THIS BOOK!
Warranty:
1
Two-Year Parts and Labor
5 Years Compressor Parts
Revision Date
08/24/2012

Advertisement

loading
Need help?

Need help?

Do you have a question about the ABT-RFC-7P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ABS ABT-RFC-7P

  • Page 1 Part number 20068, Rev 0 Pharmacy Refrigerator and Freezer Combination ABT-RFC-7P OWNER’S INSTRUCTIONS This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK! Note to Customer: This merchandise was carefully packed and thoroughly inspected before leaving our plant. Responsibility for its safe delivery was assumed by the carrier upon acceptance of the shipment.
  • Page 2: Table Of Contents

    Part number 20068, Rev 0 TABLE OF CONTENTS RECEIVING ....................3 INSTALLATION INSTRUCTIONS ..............4 REFRIGERATOR OPERATION ..............6 ELECTRONIC TEMPERATURE CONTROL ........... 7 QUICK TROUBLESHOOTING GUIDE ............12 MAINTENANCE AND CLEANING ............14 PRODUCT WARRANTY INFORMATION ..........16 BEFORE CALLING THE MANUFACTURER’S TECHNICAL SERVICE, please have the unit’s model and serial number ready as well as the problem description.
  • Page 3: Receiving

    Part number 20068, Rev 0 RECEIVING Your unit was built, packaged, and inspected with extreme care. We shipped it to you using carriers we trust with a proven track record of careful handling, good customer service, and on time delivery. Unfortunately, regardless of all of these efforts sometimes accidents happen and occasionally those accidents result in shipping damage.
  • Page 4: Installation Instructions

    Part number 20068, Rev 0 INSTALLATION INSTRUCTIONS UNCRATING Move your refrigerator as close to the final location as possible before unpacking. Remove the carton and the styrofoam strips. The location should be as close as possible to the power outlet so no extension cord is needed.
  • Page 5 Part number 20068, Rev 0 STARTING There are no compressor shipping bolts to loosen or valves to open. All that is necessary after the unit has been properly leveled is to plug the service cord into an electrical outlet When starting this new appliance, allow the cabinet to operate a minimum of four hours or until it has started cycling normally before placing product in the cabinet.
  • Page 6: Refrigerator Operation

    Part number 20068, Rev 0 REFRIGERATOR OPERATION After the unit is properly installed and power is applied, it will take some time before the system is cooled down to temperature and cycling normally. You should wait 4 hours on the first startup before beginning to add product to the unit.
  • Page 7: Electronic Temperature Control

    Part number 20068, Rev 0 ELECTRONIC TEMPERATURE CONTROL Description and Functions The Electronic Temperature Control is a digital microprocessor based temperature control, indication, and alarm system. It continuously monitors the temperature of the refrigerator/freezer through its sensor assembly. When the temperature warms to the point where it reaches the upper temperature limit, the controller sends a signal to turn on the compressor, which cools the unit.
  • Page 8 Part number 20068, Rev 0 Programming Mode Note: The programming mode gives access to several functions that are not intended for user adjustment. The procedures below provide direction to the functions that you can adjust. Please do not attempt to change any of the other functions in the programming area or your unit may be damaged or become unstable.
  • Page 9 Part number 20068, Rev 0 Hysteresis is set at 3, then the compressor will cycle from 3 to 6 degrees Celsius. To change this value, press SET and DOWN keys for 3 seconds to enter programming mode. “Hy” will display meaning Hysteresis. Press Set again and the current value will be displayed. Use the UP and/or DOWN arrow keys to adjust the value and press SET again to lock it in.
  • Page 10 Part number 20068, Rev 0 REFRIGERATOR OPERATION TEMPERATURE CONTROL NOTE: The control is preset at the factory to provide the desired air and product temperatures inside of the unit and requires no further adjustment. Please contact the manufacturer’s Technical Support Department before making any adjustments to determine if adjustment is necessary and, if so, to make sure it is performed properly.
  • Page 11 Part number 20068, Rev 0 NORMAL OPERATION After the unit is properly installed and power is applied, it will take some time before the system is cooled down to temperature and cycling normally. You should wait 8 hours on the first startup before beginning to add product to the unit.
  • Page 12: Quick Troubleshooting Guide

    Part number 20068, Rev 0 QUICK TROUBLESHOOTING GUIDE Check these items before calling for service PROBLEM: POSSIBLE CAUSE / SOULTIONS:  Electrical circuit is not 110-120V 60Hz.  The power cord is not plugged in.  No power at electrical outlet. Check to make sure Unit does not run breaker is not tripped or fuse is not blown.
  • Page 13 Part number 20068, Rev 0 PROBLEM: POSSIBLE CAUSE / SOULTIONS:  Door gasket is not sealing properly. Check for debris, cracks, and items passing through door at the gasket.  The refrigerator or freezer is facing a doorway or is underneath of air conditioning vent.
  • Page 14: Maintenance And Cleaning

    Part number 20068, Rev 0 MAINTENANCE AND CLEANING These units require very little maintenance. They should be cleaned periodically to keep them running efficiently. Use the cleaning agents and suggestions below for best results. CLEANING PART CLEANING AGENTS TIPS AND PRECAUTIONS Interior and Door Soap and water Use 2 tablespoons of baking soda in 1 quart of...
  • Page 15 Part number 20068, Rev 0 Keep your equipment clean- Use proper cleaners at recommended strength. Clean frequently to avoid build-up of hard stubborn stains. Rinse thoroughly - If chlorinated cleaners are used, you must rinse and wipe dry immediately. The sooner you wipe off standing water, the better. After wiping the unit down, allow it to air dry.
  • Page 16: Product Warranty Information

    Part number 20068, Rev 0 PRODUCT WARRANTY INFORMATION HORIZON SCIENTIFIC, INC. PRODUCT WARRANTY Horizon Scientific, Inc. warrants to the original purchaser every new Horizon Scientific, Inc. refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, when such unit is installed, used, and maintained in accordance with provided instructions, for a period of two (2) years.
  • Page 17 Part number 20068, Rev 0 OR NOT INSURED, SHALL NOT EXCEED THE COST OF THE PRODUCT(S) GIVING RISE TO THE CLAIM OR LIABILITY. WARRANTY IS NOT TRANSFERABLE. This warranty is not assignable and applies only in favor of the original purchaser/user to whom delivered. Any such assignment or transfer shall void the warranties herein made and shall void all warranties, express or implied, including any warranty of merchantability or fitness for a particular purpose.
Save PDF