Section 3: Safety Related Adjustments; R564 Confi Rmation Method (Hv Hold-Down Confi Rmation) And Readjustments; B+ Voltage Confi Rmation And Adjustment - Sony TRINITRON KV-27FA310 Service Manual

Trinitron series color television
Table of Contents

Advertisement

3-1. X R564 CONFIRMATION METHOD
(HV HOLD-DOWN CONFIRMATION) AND
READJUSTMENTS
The following adjustments should always be performed when replacing
the following components which are marked with Y on the schematic
diagram:
Part Replaced (Y)
DY, T585, CRT, IC001, IC561,
IC600, IC604, C506, C507,
C508, C510, C511, C513,
C514, L588, D566, D567,
D568, PH602, R526, R564,
R565, R566, R851, T510,
T511..........A Board
Preparation Before Confi rmation
1. Using a Variac, apply AC input voltage: 120 ± 2 VAC.
2. Turn the POWER switch ON.
3. Input a white signal and set the PICTURE and BRIGHTNESS
controls to maximum.
4. Confi rm that the voltage between C566 (+) or TP30 and ground is
more than 99VDC.
Hold-Down Operation Confi rmation
1. Connect the current meter between Pin 11 of the FBT (T585) and the
PWB land where Pin 11 would normally attach (See Figure 1 on the
next page).
2. Input a dot signal and adjust the ABL current to follow with the
PICTURE and BRIGHTNESS control: IABL = 140 ± 100µA.
3. Confi rm the voltage of A Board TP-23 is 135.6 ± 1.0VDC.
4. Connect the digital voltmeter and the DC power supply via Diode
1SS119 to C566 (+) and ground (See Figure 1 on next page).
5. Increase the DC power voltage gradually until the picture blanks out.
6. Turn DC power source off immediately.
7. Read the digital voltmeter indication
(Standard 114.6 +OVDC/-0.3DC).
8. Input 100 IRE White Signal and adjust the ABL current to follow with
the PICTURE and BRIGHTNESS control: IABL = 1820µA ± 200µA.
9. Repeat steps 4 through 7.
KV-27FA310/27FS120/29FA310/29FS120

SECTION 3: SAFETY RELATED ADJUSTMENTS

Adjustment (X)
HV HOLD-DOWN
R564
Hold-Down Readjustment
If the setting indicated in Step 2 of Hold-Down Operation Confi rmation
cannot be met, readjustment should be performed by altering the
resistance value of R564 component marked with X.
3-2. B+ VOLTAGE CONFIRMATION AND
ADJUSTMENT
Note: The following adjustments should always be performed when
replacing the following components, which are marked with Y on the
schematic diagram on the A Board:
A BOARD:
Y IC604, PH602
1. Using a Variac, apply AC input voltage: 130 + 2.0 / - 0.0 VAC.
2. Input a DOT pattern at Q.C.
3. Set the PICTURE and the BRIGHTNESS controls to minimum.
4. Confi rm the voltage of A Board between TP-23 & Ground is =135.6
± 1VDC.
5. If step 4 is not satisfi ed, replace the components listed above, then
repeat steps 1 throught 3.
KV-27FA310/27FS120/29FA310/29FS120
T585
FBT
ammeter
3.0 mA DC
range
ABL
-
+
A
IABL
17