Picomed PicoCombi Documentation

Loudspeaking analog telephone and doorphone

Advertisement

Quick Links

Environmental control
Documentation for
PicoCombi Loudspeaking analog
telephone and doorphone
Brokelandsheia, N-4993 Sundebru, Ph +47 3711 9950 Fax +47 3711 9951 E-mail: firmapost@picomed.no Foretaksnr 962 211 631 MVA

Advertisement

Table of Contents
loading

Summary of Contents for Picomed PicoCombi

  • Page 1 Environmental control Documentation for PicoCombi Loudspeaking analog telephone and doorphone Brokelandsheia, N-4993 Sundebru, Ph +47 3711 9950 Fax +47 3711 9951 E-mail: firmapost@picomed.no Foretaksnr 962 211 631 MVA...
  • Page 2: Table Of Contents

    Telephone book ....................10 3.5.10 Tone generating....................11 3.5.11 Doorphone 1 and 2 ................... 11 3.5.12 Power failure ....................11 3.5.13 Accessories....................... 12 3.5.14 User manual - quick guide ................13 Programming ........................15 PicoCombi loudspeaking analog telephone and doorphone Page 2.
  • Page 3 Door indicator ....................24 7.2.5 External switches....................25 7.2.6 External loudspeaker ..................25 7.2.7 External microphone ..................25 Jumpers........................25 Default (recycling) ....................25 Technical data ......................26 CE markings ......................26 Drilling template......................28 PicoCombi loudspeaking analog telephone and doorphone Page 3.
  • Page 4: Introduction

    In addition a remote controller which transmits infrared signals (IR) should be used to control the device to get full access to all functions. PicoCombi can be connected to 1 or 2 doorphone outdoor units which are not delivered with the apparatus.
  • Page 5: Keys

    • How to save numbers (up to 50 pcs) in the telephone book are described in chapter 4.2. • To get the most out of all functions in the PicoCombi, the installer should go through all settings and make any changes in the advanced programming mode. This mode are described in chapter 4.3.
  • Page 6: User Manual

    3.1 Incoming call PicoCombi gives a ringing signal to indicate an incoming call. You may hook off by the use of the remote controller, key on device, external switch or by the help of the automatic answering function if this is enabled.
  • Page 7: Telephone Conversation

    3.3 Telephone conversation The telephone line will be active until: • The user disconnects (”hook on”) with the remote controller, key on PicoCombi, or an external switch. • The person you are talking to, hooks on. • If the conversation is started by the automatic answering function, it will be ended when the predefined conversation time (programmable in advanced programming mode) expires.
  • Page 8: Hook Off

    Open/unlock door (5 seconds active output) and thereafter Door key on device terminate conversation with doorphone. If beeper in doorlock are mounted, the user will normally hear this sound through the doorphone system. PicoCombi loudspeaking analog telephone and doorphone Page 8.
  • Page 9: Conversation With Doorphone, Parked Telephone

    3.5.5 Volume adjustment Volume adjustments for the telephone function on PicoCombi may be adjusted with the remote controller in 5 steps. If the volume has been changed, the new value is stored and used for later telephone conversations. When pressing ”F” on remote controller the volume will increase and it will be indicated by one short ”beep”...
  • Page 10: Voice Message

    The automatic answering function can be turned on and off with an IR-remote controller or with the ”automatic answering function key” on PicoCombi. The function will be active both for telephone and for the doorphone. A light indicator will illuminate when the function is enabled.
  • Page 11: Tone Generating

    A pause (”F”) can be a part of a number in the telephone book. PicoCombi will wait a predefined time before the numbertransmitting continues if ”F” is a part of the telephone number.
  • Page 12: Accessories

    The following accessories are available: • External switches to control telephone line, doorphone and phone book numbers 1-3. • Outdoor units for doorphone. • External IR-sensors. • External loudspeaker. • External microphone. PicoCombi loudspeaking analog telephone and doorphone Page 12.
  • Page 13: User Manual - Quick Guide

    Disconnect doorphone - return to parked telephone conversation • A long "beep" indicates maximum volume • Press key ”E” (does not open door) Brokelandsheia, N-4993 Sundebru, Ph +47 3711 9950 Fax +47 3711 9951 E-mail: firmapost@picomed.no Foretaksnr 962 211 631 MVA...
  • Page 15: Programming

    • Programming – default/recycling: Restore default settings. Observe that: • When installing a PicoCombi you should as a first job enter advanced programming mode and record speech to the auditive feedback (point 31 in the list). This should be done because this feedback will be a very good help in programming mode.
  • Page 16: Programming - Advanced

    Especially with the built in speech functions which are available. When installing a PicoCombi you should as a first job enter advanced programming mode and record speech to the auditive feedback (point 31 in the list). This should be done because this feedback will be a very good help in programming mode.
  • Page 17 Stored digit/ –, nnn (-) Saved Activate voicemessage(s) for situation 1. Empty Pressed digit (Answer doorphone) Stored digit/ –, nnn (-) Saved Activate voicemessage(s) for situation 2. Empty Pressed digit (Unlock/open door) PicoCombi loudspeaking analog telephone and doorphone Page 17.
  • Page 18: Additional Explanations For The Table Above

    Finish the sequence. Start with "0", go on with ”1” and so on. ”Pause” is the last word. Important! • When installing a PicoCombi you should as a first job enter advanced PicoCombi loudspeaking analog telephone and doorphone Page 18.
  • Page 19: Programming - Ir-Training

    4.4 Programming – IR-training When entering this mode, then the PicoCombi automatically will activate the trained IR- format, while the other IR-formats will remain unaltered. This means that it is possible to use more than one remote controller to control the device. To enter IR-training mode, only keys on the device shall be used: 1.
  • Page 20: Programming - Back To Default Settings

    4.5 Programming – back to default settings There is a 2-stage process to execute to get the PicoCombi back to default settings. This sequence is controlled by the keys on the device. • Step 1 restores all changeable parametres back to default settings.
  • Page 21: When Errors Arise

    • Frontfoil. Productname, light indicators and keys are visually viewed on it. 7.1 Fixed mounting PicoCombi are designed to be placed on a flat surface, or it can be hanged vertically with the help of the built-in screwholes. • Ensure that cables not are crushed between the device and surface.
  • Page 22: Fixed 12 Vdc And External Ir-Sensor

    Controls LED on external IR-sensor(s). IR-signal from external IR-sensor(s). 1 or 2 external IR-sensors (Picomed ES2) can be connected to the terminal strip. They will be supplied with 0 and +12 VDC together with LED signal from the device. The IR-signal wires are also connected at the same terminal strip.
  • Page 23: Doorphone

    7.2.2 Doorphone A doorphone (outdoor unit) named Picomed EFP can be connected as the table shows on the terminal strips DP1 and DP2 on PicoCombi. DP1 and DP2 are, with exception of connection D.SW at DP1, equal. They have the following connections with recommended colours: PicoCombi loudspeaking analog telephone and doorphone Page 23.
  • Page 24: Multiple Indoor Units

    It is possible to have up to 4 PicoCombi' s connected to the same telephone line/doorphone line. If more than one PicoCombi shall be used, use 1 power supply for each, and then connect all wires from one to another in parallell both for telephone and doorphone.
  • Page 25: External Switches

    7.4 Default (recycling) The following shall be done on Picomeds PicoCombi when it shall be used by a new user. If neccessary, make a copy of this page, fill inn serial number, version and tick off the points which are done with signature and date at each point, and file it as your routines requires.
  • Page 26: Technical Data

    Signals, voice messages, telephone numbers and other data will be deleted. Store. 7.5 Technical data Type • Picomed PicoCombi loudspeaking IR-controlled analog telephone and doorphone. Operate • Picomed IR-remote controller with 16 channels. • An other IR-remote controller with 16 channels.
  • Page 28: Drilling Template

    8 Drilling template...

Table of Contents