Revision history
When changes are made on the product or in the documentation, this will be given a revision
number. The list below keeps track of these changes.
Date
Name
19.10.05
Bent-Håvard Sollid.
01.07.06
Bent-Håvard Sollid.
01.08.08
Bent-Håvard Sollid.
01.01.12
Bent-Håvard Sollid.
Contents - Documentation EFP 2005
1
Introduction ...................................................................................................................... 2
2
Getting started, installation ............................................................................................. 2
3
User manual ...................................................................................................................... 2
3.1
Accessories ................................................................................................................. 3
4
Maintenance ...................................................................................................................... 3
4.1
Cleaning ..................................................................................................................... 3
4.2
Outdoor use ................................................................................................................ 3
5
Troubleshooting ................................................................................................................ 3
5.1
If errors arise .............................................................................................................. 4
6
Technical information ...................................................................................................... 4
6.1
Fixed mounting .......................................................................................................... 4
6.2
Electrical connections ................................................................................................ 4
6.2.1 Outdoor unit ........................................................................................................... 4
6.2.2 Amplifier box ......................................................................................................... 4
6.2.3 Wiring diagram for Picolo/PicoCombi version I ................................................... 6
6.2.4 Wiring diagram for Picolo/PicoCombi version II .................................................. 7
6.2.5 Wiring diagram for Erifox PABX .......................................................................... 8
6.3
Default (recycling) ..................................................................................................... 9
6.4
Technical data ............................................................................................................ 9
6.5
CE markings ............................................................................................................... 9
Brokelandsheia, N-4993 Sundebru, Ph +47 3711 9950 Fax +47 3711 9951 E-mail:
Environmental control
Documentation for
EFP 2005 doorphone
To be used together with
Description
First version with English text.
EC Declaration of Conformity updated with new
directives.
Added WEEE icon.
Changed revisionlist to new type.
New version of outdoor unit:
- Ch 6.2.1, changed text.
- Ch , 6.2.3, 6.2.4, changed wiring diagram.
Added wiring diagram for the new version of PicoCombi,
MK II.
firmapost@picomed.no Org.no 962 211 631 MVA

Advertisement

Table of Contents
loading

Summary of Contents for Picomed EFP 2005

  • Page 1: Table Of Contents

    - Ch , 6.2.3, 6.2.4, changed wiring diagram. 01.01.12 Bent-Håvard Sollid. Added wiring diagram for the new version of PicoCombi, MK II. Contents – Documentation EFP 2005 Introduction ........................2 Getting started, installation ..................... 2 User manual ........................2 Accessories ......................... 3 Maintenance ........................
  • Page 2: Introduction

    It is possible to regulate the volume from the outdoor unit, but it is recommended that the preset value is kept unaltered. EFP 2005 shall be powered with 12 VDC.
  • Page 3: Accessories

    The outdoor units frontfoil can be replaced if the users name shall be changed. 4 Maintenance EFP 2005 doorphone is developed to work without any need for adjustment etc. There are no fuses or batteries which has to be changed.
  • Page 4: If Errors Arise

    There are 3 terminal blocks in the amplifier box and each of them have 6 connections. Connections are made for maximum 2,5 mm cable. Remove 6 mm of the insulation. Terminal block at the lower right is for cable to indoor unit. EFP 2005 – loudspeaking doorphone Page...
  • Page 5 DB is DoorBell, one-pole switch in outdoor unit. Connects GND back to indoor unit. LS is LoudSpeaker, sound to loudspeaker in outdoor unit. Non-polarized. Mic+ and Mic- is sound from the outdoor units microphone. Polarized. EFP 2005 – loudspeaking doorphone Page...
  • Page 6: Wiring Diagram For Picolo/Picocombi Version I

    6.2.3 Wiring diagram for Picolo/PicoCombi version I EFP 2005 – loudspeaking doorphone Page...
  • Page 7: Wiring Diagram For Picolo/Picocombi Version Ii

    6.2.4 Wiring diagram for Picolo/PicoCombi version II OBS: this is for PicoCombi MK II – not same diagram as for MKI. EFP 2005 – loudspeaking doorphone Page...
  • Page 8: Wiring Diagram For Erifox Pabx

    6.2.5 Wiring diagram for Erifox PABX EFP 2005 – loudspeaking doorphone Page...
  • Page 9: Default (Recycling)

    6.3 Default (recycling) The following shall be done on Picomeds EFP 2005 when it shall be used by a new user. If necessary, make a copy of this page, fill inn serial number, version and tick off the points which are done with signature and date at each point, and file it as your routines requires.