Cleaning And Maintenance - Vanguard VYS18NWA Owner's Manual

Unvented (vent-free) natural gas log heater flame-max series
Table of Contents

Advertisement

CLEANING AND
MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, pet hair, etc.
CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper
amount of air to mix with the gas. This
provides a clean burning flame. Keep these
holes clear of dust, dirt, lint, and pet hair.
Clean these air inlet holes prior to each
heating season. Blocked air holes will cre-
ate soot. We recommend that you clean the
unit every every three months during opera-
tion and have heater inspected yearly by a
qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store, or
home center may carry compressed air in a
can. You can use a vacuum cleaner in the
blow position. If using compressed air in a
can, please follow the directions on the can.
If you don't follow directions on the can, you
could damage the pilot assembly.
1. Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.
2. Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 25).
3. Blow air through the ports/slots and
holes in the burner.
105189
4.
Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hair with a soft cloth or vacuum
cleaner nozzle.
5.
Blow air into the primary air holes on
the injector holder.
6.
In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.
Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 26). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.
Burner
Tube
Primary Air Inlet
Holes (Shape of
Holes May Vary
by Model)
Figure 25 - Injector Holder On Outlet
Burner Tube
Burner
Tube
Pilot
Assembly
Pilot Air
Inlet Hole
Figure 26 - Pilot Inlet Air Hole
21
OWNER'S MANUAL
LOGS
• If you remove logs for cleaning, refer to
Installing Logs, page 13, to properly re-
place logs.
• Replace log(s) if broken or chipped
(dime-sized or larger).
MAIN BURNER
Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no
flame present. If so, turn off heater and let
cool. Remove blockage. Blocked burner
flame holes will create soot.
Injector Holder
(May Be Brass
or Aluminum
Depending on
Model)
Ports/Slots

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vys24nwaVys30nwa

Table of Contents