Lever Frame Assembly Exchange; Head Assembly Exchange - AMSTRAD PC1512 Service Manual

Personal computer/monochrome monitor/colour monitor
Table of Contents

Advertisement

Ilj^
4-5
Lever
Frame Assembly Exchange
(See
Figure
4-5)
4-5-1
Lever
Frame Assembly Removal
a)
Remove
the printed
circuit
board as described
in
4-1-1.
b)
Remove
the
lever
as described
in
4-2-1.
c)
Remove
the
front plate
as described
in
4-3-1
d)
Remove
the
eject
assembly
as
described
in
4-4-1.
e)
Unfasten
the
four lever
frame assembly
fix
screws.
f)
Lift
the
lever
frame assembly
slightly
making
sure
that
the top
head
is
not
raised,
and remove
the
slidinh to
the
left.
4-5-2
Lever
Frame Assembly
Jvlounting
and
Adjustment.
a) Lift
the top
head
slightly
and
slide
the
pad mounting
part of
the
lever
frame assembly under
the
top head.
b)
Secure
the
lever
frame
assembly
with
four
screws.
c)
Mount
the
eject
assembly
as described
in
4-4-2.
d)
Mount
the
front
plate
as described
in
4-3-2.
e)
Mount
the
lever
as described
in
4-2-2.
f)
Unfasten
the
two screws
of
hub
shaft
holder
and
centre by
moving
the
hub up and
down
several
times
and secure
the
two
screws.
g)
Mount
the printed
circuit
board ad described
in
4-1-2.
h)
After
mounting,
adjust the index burst
time.
(Refer
to
5-5).
4-6
Stepping Motor
Assembly Exchange
(See
Figure
4-6)
4-6-1
Stepping Motor
Assembly Removal
a)
Remove
the printed
circuit
board as described
in
4-1-1.
b)
Unfasten
the
head assembly
metal
belt
fix
screw.
c)
Unfasten
the stepping
motor
belt
fix
screw and
remove
the
keep
plate.
d)
Unfasten
the
two
stepping
motor assembly
fix
screws.
e)
Lift
the stepping
motor assembly upward,
then
slide
it
to
the
left
to
remove
from the metal
belt.
f)
Disconnect
the stepping
motor assembly
cord from the hook.
4-6-2
Stepping Motor
Assembly Mounting
Adjustment
a)
Keep
the metal
belt
in
the loop
form,
insert
the stepping
motor assembly,
mount
the metal
belt
and keep
plate with
screws.
b)
Align
the
oval
hole
of
the stepping
motor mounting
plate with
the guide
pin
and mount
the
stepping
motor assembly
with
two
screws.
Temporary
tightening
of
screws
are
required.
c)
Pull
the
tip
of
the metal
belt
and mount
the metal
belt
on
the
tip
of
the
head assembly
with
a screw.
d)
Move
the
head assembly back and
forth
and check
that
the metal
belt
is
not
twisted.
If
twisted,
slightly
loosen the metal
belt
fix
screws on
the stepping
motor assembly and head
assembly,
and
move
the
head assembly back and
forth
several times.
Fasten
the
screws
tightly.
e)
Place the stepping
motor assembly
cord
on
the
hook.
f)
Mount
the printed
circuit
board as described
in
4-1-2.
g)
Adjust the
radial
track
after
mounting.
(Refer
to
5-2).
Caution:
Do
not
reuse
the metal
belt
removed
from the
head
assembly.
4-7
Head
Assembly Exchange
(See
Figure
4-7)
4-7-1
Head
Assembly Removal
a)
Remove
the
printed
circuit
board as described
in
4-1-1.
b)
Remove
the
lever
as described
in
4-2-1
c)
Remove
the
front plate
as described
in
4-3-1.
d)
Remove
the
eject
assembly
as
described
in
4-4-1.
e)
Remove
the
lever
framne assembly
as described
in
4-5-1
f)
Remove
the stepping
motor assembly
as described
in
4-6-1.
g)
Unfasten
the
PCB
post
fix
screws and remove
the
PCB
post.
h)
Unfasten
the
two screws
fastening the
guide
shaft
keepers
A
and B and remove keepers
A
and
B.
i)
Lift
the
guide
shaft rear
edge and remove
the
guide
shafts
in
a
backward
direction, individually.
Be
careful not to
damage
guide
shafts or
mix the
right
and
left
shafts.
j)
Carefully
remove
the
head
assembly.
4-7-2
Head Assembly
Mounting and Adjustment
a) Fit
the
two
guide
shafts
in
the
head assembly
without mixing the
right
and
left,
and mount
in
the
housing
while holding the
guide
shaft.
b)
Secure
guide
shaft
keepers
A
and B
using
four
screws.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc-mmPc-cm

Table of Contents