Vitoladens – ordering fuel oil
Fuel oil quality
The Vitoladens 300-W and Vitola-
dens 333-F are approved for opera-
tion with low sulphur fuel oil to
DIN 51603-EL-1 (max. sulphur con-
tent 50 ppm).
Fuel oil additives
Fuel oil additives are materials that
can be used providing they offer the
following characteristics:
&
Improvement of the storage stability
of the fuel.
&
Improvement of the thermal stability
of the fuel.
&
Reduction of odour development
during filling.
Combustion improvers
Combustion improvers are additives
for optimising fuel oil combustion.
Viessmann oil burners do not require
combustion improvers, as these bur-
ners operate with clean and efficient
combustion.
Biofuels
Bio fuels are made from vegetable oil,
e.g. sunflower or rape seed oil.
If in doubt refer to your local heating contractor.
Vitoladens - Ordering fuel oil
A condensate neutralising system is
not required (according to Code of
Practice ATV-DVWK-A 251 [Ger-
many]) when using this low sulphur
fuel.
!
Please note
Fuel oil additives can create
residues and impair the safe
operation of your heating sys-
tem.
The use of fuel oil additives
that leave residues is not per-
missible.
!
Please note
Combustion improvers can cre-
ate residues and impair the
safe operation of your heating
system.
The use of combustion impro-
vers that leave residues is not
permissible.
!
Please note
Bio fuels can lead to damage
on Viessmann oil burners.
Their use is not permissible.
43