Mechanism Adjustment; Optical Pickup Grating Inspecting Method - Kenwood DM-3090 Service Manual

Stereo minidisc recorder
Table of Contents

Advertisement

DM-3090

Mechanism Adjustment

1. Optical pickup grating inspecting method

42 pin of IC 1101
GND (TP1131)
100K
26 pin of IC 1101
EOUT (TP1133)
470p
470p
25 pin of IC 1101
100K
FOUT (TP1132)
Figure 23-1 Optical Pickup Grating Deviation
Measuring Method
After the automatic adjustment is performed in the AUTO
mode (test mode) with the aid of high refection MD disc
("COMPLATE" is displayed), the Lissajous's waveform (x-y) is
adjusted.
1. Slightly loosen the 3 screws of spindle moto, and maken an
adjustment, observing the Lissajous's waveform.
2. After adjustment tighten the screw in arder of 1 , 2 , 3 .
2. Jitter adjustment and checking method
1pin of IC 1201
(TP1274)
EFMMON
88 pin of IC 1201 (TP1275)
GND
Figure 23-3 Jitter connection diagram
After performing automatic adjustment in AUTO mode of
TEST mode using the low reflection MD disc, check this jitter
in pit continuous playback and groove continuous playback
mode.
5P extension flat cable
CNP1601(Bottom side)
CNP1602
CNP1603
CNP1604(Bottom side)
6P-2P extension connector
30
ADJUSTMENT
OSILLOSCOPE
a
GND CH1 CH2
b
X
Y
LISSAJOUS'S WAVEFORM
Less thana:b = 3:1
jitter Meter
2P extension connector
CNP1252
From
motor
From mecha-
nism switch
PWB
CNP1101
28Pextension flat cable
MD Main PWB
Figure 23-4
1
3
2
Spindle Motor
Adjusting hole
3
Spindle motor
1
Check the Lissajou's waveform,
shifting the mounting position with
a screwdriver (to be fitted into the
disc motor adjusting hole).
adjusting
hole
2
Figure 23-2
From Magnetic Head
Extension PWB for service
Fit the extension PWB for service to the mechanism
From Optical
Pickup Unit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents