Picomed PicoPhone Documentation

Loudspeaking analog telephone

Advertisement

Quick Links

Environmental control
Documentation for
PicoPhone Loudspeaking analog
telephone
Brokelandsheia, N-4993 Sundebru, Ph +47 3711 9950 Fax +47 3711 9951 E-mail: firmapost@picomed.no Foretaksnr 962 211 631 MVA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PicoPhone and is the answer not in the manual?

Questions and answers

Summary of Contents for Picomed PicoPhone

  • Page 1 Environmental control Documentation for PicoPhone Loudspeaking analog telephone Brokelandsheia, N-4993 Sundebru, Ph +47 3711 9950 Fax +47 3711 9951 E-mail: firmapost@picomed.no Foretaksnr 962 211 631 MVA...
  • Page 2: Table Of Contents

    E0404 7.6, 8 25, 26 New version of EC Declaration of Conformity. 30.01.04 Added information in drilling template. Contents – Documentation PicoPhone Introduction ........................4 Getting started ........................4 2.1 Keys ..........................5 2.2 Light indicators.......................5 2.3 Connections ........................5 User manual ........................6 3.1 Incoming call ........................6...
  • Page 3 7.2.1 Fixed 12 VDC and external IR-sensor ..............17 7.2.2 Multiple indoor units ....................19 7.2.3 External switches....................19 7.2.4 External loudspeaker ....................19 7.2.5 External microphone.....................19 7.3 Jumpers.........................19 7.4 Default (recycling)......................19 7.5 Technical data.......................20 7.6 CE markings .........................20 Drilling template ........................22 PicoPhone loudspeaking analog telephone Page 3.
  • Page 4: Introduction

    Picomeds IR-remote controllers, or it is possible to let the device be controlled by a foreign IR-remote controller. There is a built-in IR-receiver, and in addition it is possible to connect two external IR-sensors. PicoPhone is designed for indoor use. Picomeds loudspeaking phones can be delivered in different variants. These are:  Picolo –...
  • Page 5: Keys

     How to save numbers (up to 50 pcs) in the telephone book are described in chapter 4.2.  To get the most out of all functions in the PicoPhone, the installer should go through all settings and make any changes in the advanced programming mode. This mode are described in chapter 4.3.
  • Page 6: User Manual

    3.1 Incoming call PicoPhone gives a ringing signal to indicate an incoming call. You may hook off by the use of the remote controller, key on device, external switch or by the help of the automatic answering function if this is enabled.
  • Page 7: Functions

    Generate R-key signal = hook flash. No function. End conversation. Telephone key on device Volume adjustment in steps from 1-5. Automatic answering key Enable/disable automatic answering function. Automatic on device answering indicator changes status. PicoPhone loudspeaking analog telephone Page 7.
  • Page 8: Volume Adjustment

    3.4.3 Volume adjustment Volume adjustments for the telephone function on PicoPhone may be adjusted with the remote controller in 5 steps. If the volume has been changed, the new value is stored and used for later telephone conversations. When pressing ”F” on remote controller the volume will increase and it will be indicated by one short ”beep”...
  • Page 9: Telephone Book

    A pause (”F”) can be a part of a number in the telephone book. PicoPhone will wait a predefined time before the numbertransmitting continues if ”F” is a part of the telephone number.
  • Page 10: User Manual - Quick Guide

     PicoPhone automatically calls last used number Volumecontrol  Press key ”F” when you are speaking in the phone  A long "beep" indicates maximum volume Brokelandsheia, N-4993 Sundebru, Ph +47 3711 9950 Fax +47 3711 9951 E-mail: firmapost@picomed.no Foretaksnr 962 211 631 MVA...
  • Page 11: Programming

     Programming – default/recycling: Restore default settings. Observe that:  When installing a PicoPhone you should as a first job enter advanced programming mode and record speech to the auditive feedback (point 31 in the list). This should be done because this feedback will be a very good help in programming mode.
  • Page 12: Programming - Advanced

    Especially with the built in speech functions which are available. When installing a PicoPhone you should as a first job enter advanced programming mode and record speech to the auditive feedback (point 31 in the list). This should be done because this feedback will be a very good help in programming mode.
  • Page 13 Empty Not in use. Empty Not in use. Stored digit/ –, nnn (-) Saved Activate voicemessage(s). Empty Pressed digit (Answer doorphone) –, nnn (-) Activate voicemessage(s). Stored digit/ Saved Empty Pressed digit (Unlock/open door) PicoPhone loudspeaking analog telephone Page 13.
  • Page 14: Additional Explanations For The Table Above

    Start with "0", go on with ”1” and so on. ”Pause” is the last word. Important!  When installing a PicoPhone you should as a first job enter advanced programming mode and record speech to the auditive feedback (point 31 in the list).
  • Page 15: Additional Explanations For The Table Above

    To enter IR-training mode, only keys on the device shall be used. There is an additional ("hided") key on PicoPhone to be used. It is placed between and a little bit above the two existing keys. In the text beneath it is refered to as "hided"...
  • Page 16: Maintenance

     Trained IR will be deleted. 5 Maintenance Picomeds PicoPhone loudspeaking IR-controlled loudspeaking analog telephone is developed to work without any sceduled maintenance. The equipment should be cleaned when neccessary. Wipe the equipment with a slightly damp cloth or an antistatic cloth. Never use a dry cloth, while this result in risk of static charges.
  • Page 17: When Errors Arise

     Frontfoil. Productname, lightindicators and keys are visually viewed on it. 7.1 Fixed mounting PicoPhone are designed to be placed on a flat surface, or it can be hanged vertically with the help of the built-in screwholes.  Ensure that cables not are crushed between the device and surface.
  • Page 18 IR-signal from external IR-sensor(s). 1 or 2 external IR-sensors (Picomed ES2) can be connected to the terminal strip. They will be supplied with 0 and +12 VDC together with LED signal from the device. The IR-signal wires are also connected at the same terminal strip. There is a lightindicator placed in the front of the main PCB which indicates that IR is received.
  • Page 19: Multiple Indoor Units

    7.2.2 Multiple indoor units It is possible to have up to 4 PicoPhone's connected to the same telephone line. If more than one PicoPhone shall be used, use 1 power supply for each, and then connect the telephone lines from one unit to another i parallell.
  • Page 20: Technical Data

    7.5 Technical data  Picomed PicoPhone loudspeaking IR-controlled analog Type telephone.  Picomed IR-remote controller with 16 channels. Operate  An other IR-remote controller with 16 channels.  Keypad for main functions.  External switches may be connected. Power supply Enclosed: Mascot 8713 Medical.
  • Page 22: Drilling Template

    8 Drilling template                                                       !             ...

Table of Contents