Inter-m ARM-911 Operation Manual

Automated remote message

Advertisement

Inter-M, Ltd. (Korea) began operations in 1983.
Since then, Inter-M has grown to become one of the largest manufacturers
of professional audio and commercial sound electronics equipment in the world.
Inter-M has gained worldwide recognition for its own branded products,
as well as private label manufacturing of electronics sold under other names (OEM).
The company is no longer just a Korean company, but rather a global company
that is truly international in scope, with factories and offices in Korea and China,
and sales and marketing operations located in Japan, Europe, and the U.S. .
With more than 850 employees around the globe,
Inter-M is well-poised for further growth and expansion.
Inter-M mericas, INC.
13875 RTESI BLVD. CERRITOS, C 90703 US
TEL : +1-562-921-0313, F X : +1-562-921-0370
Home Page : http://www.inter-m.net, E-mail : info@inter-m.net
Inter-M Corporation
SEOUL OFFICE:653-5 B NGH K-DONG, DOBONG-GU, SEOUL, KORE
TEL : +82-2-2289-8140~8, F X : +82-2-2289-8149
Home Page : http://www.inter-m.com, E-mail : overseas@inter-m.com
MADE IN KOREA
September 2013 133

Advertisement

Table of Contents
loading

Summary of Contents for Inter-m ARM-911

  • Page 1 Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).
  • Page 2 Operation anual utomated Remote Message RM-911...
  • Page 3 UTOM TED REMOTE MESS GE Welcome Welcome personal welcome to you from the management and employees of Inter-M ll of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products. We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete satisfaction, we will endeavor to make things right.
  • Page 4: Table Of Contents

    UTOM TED REMOTE MESS GE Contents Contents Unpacking ............................2 Installation Environment............................2 Important Safety Instructions......................2 Features ............................3 Front Panel ............................4 Rear Panel ............................5 Operation Method 1. SD Disk Function .........................7 2. SD Disk Copy Function ........................7 3. Telephone Paging........................8 Web-browser Interface Configuration 1.
  • Page 5: Unpacking

    UTOM TED REMOTE MESS GE Unpacking Unpacking lthough your RM-911 is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation. s with most electronic devices, we strongly recommend you retain the original packaging.
  • Page 6: Features

    UTOM TED REMOTE MESS GE Features Features - Direct broadcasting of Emergency Message By pressing one of 10 instant play buttons, message file can be directly played. - SD Card Backup Backup SD card is installed inside so that Front SD card can be copied to the backup SD card. - MP3 Decoding MP3 file format is supported.
  • Page 7: Front Panel

    UTOM TED REMOTE MESS GE Front Panel Front Panel 1. SD C RD COVER 2GB SD Card is installed. Be sure the direction when insert a SD card into the slot. Only 2GB memory can be used. 2. INDIC TING LED The LED is lit when the button is pressed.
  • Page 8: Rear Panel

    UTOM TED REMOTE MESS GE Rear Panel Rear Panel C INLET Connect the power cable which is supplied with the unit. 2. POWER SW Use this switch to turn the power on or off. 3. DC INPUT Connect a DC24V power source to this terminal. Make sure the polarity when make a connection.
  • Page 9 UTOM TED REMOTE MESS GE 8. TEL IN Connect to a telephone exchange system for paging purposes. If a DTMF signal is inputted, then the unit decode the DTMF tone and play the corresponded file which is in the SD card. 9.
  • Page 10: Operation Method

    UTOM TED REMOTE MESS GE Operation Method Operation Method 1. SD Disk Function 2GB SD memory is installed both front SD card and internal Backup SD card. (1) Take out the SD memory from the unit. Screw off the cover. Push and release the center of the SD memory and then take out the SD memory.
  • Page 11: Telephone Paging

    UTOM TED REMOTE MESS GE (4) Plug the SD memory into the slot. [NOTE] 1. When the SD memory is empted then, the indicating LED does not lit even though the Instant Play button is pressed. 2. RM-911 can play MP3 files. MP3 : 44.1kHz sampling frequency, 16bit and 64kbps~320kbps bit rates.
  • Page 12: Web-Browser Interface Configuration

    UTOM TED REMOTE MESS GE Web-browser Interface Configuration Web-browser Interface Configuration 1. ccessing to the RM-911 Web-browser Connecting the TCP/IP port to your computer. Change the IP address of the computer (ex. 192.168.1.100) and change the Gateway to 192.168.1.99. ccess to the web-browser by typing in the address bar of your internet browser such Explorer, Firefox or Safari the factory default IP address (192.168.1.99).
  • Page 13: Time Signal Setting

    UTOM TED REMOTE MESS GE 1) Collect information on your network configuration. range of free IP addresses that can be allocated to the RM-911 unit(s) without network conflicts. - The correct subnet mask. - The address of the Gateway and the DNS servers if you want your RM-911 to be able to connect to the Internet.
  • Page 14 UTOM TED REMOTE MESS GE 1) USE ctivates the time signal schedule. 2) View Table Shows the current schedule. The following window will be opened when you click ‘New’. (1) Name : Indicates the title of the Schedule. (2) Files : Put your mouse over the icon and the set file name will appear. (3) Hour : Displays the set start and end time.
  • Page 15 UTOM TED REMOTE MESS GE 4) Delete : Press to delete a schedule and the following screen will appear: (1) Delete : Delete the selected schedule. (2) Select all : Select or clear the entire list. 5) Modify : Modify the time schedule. fter modify the schedule, press the pply button.
  • Page 16 UTOM TED REMOTE MESS GE 6) Holiday Holiday schedule programming. The schedule is not broadcasted on the selected date. The following screen will appear. (1) dd : dd a holiday. (2) Enable : Select EN BLE to use the holiday setup. (3) Start/End Date : Set the start date and the end date of the holiday setup.
  • Page 17: Priority Setting

    UTOM TED REMOTE MESS GE 8) Source File To manage add or delete source files. (1) Select : Select a file. Multiple file selection is possible by using the ‘CTRL‘ key in the keyboard. (2) Delete : Delete the selected file. (3) Preview : Play the selected file to check.
  • Page 18: Ux Input Setting

    UTOM TED REMOTE MESS GE 5. UX Input Setting Default setting is: UX 1 – Mic level, Phantom ‘off’. UX 2 – Line level (-10dBu), Phantom ‘off’. 6. Level Setting Set the volume of the inputs and output. Level can be set from 0 to 100. Default is 50. RM-911...
  • Page 19: Eq Setting

    UTOM TED REMOTE MESS GE 7. EQ Setting The EQ of every input can be set individually. Each input is set by selecting the respective channel button. Default value is 0 for each band. 20 Steps can be set from -10 to +10. High pass filter (65Hz) can be set for each input.
  • Page 20: Rm Setting

    UTOM TED REMOTE MESS GE 8. RM Setting Password of RM-911D or RM-911W can be set. To use password, check the use box. Type in 4 digit (0, 1, ..., 9) of password and press the Set button. If password is set, then the password have to be entered before select the INST NT PL Y button on RM-911D or RM-911W and select the T LK button.
  • Page 21: Message Control

    UTOM TED REMOTE MESS GE 9. Message Control Message playback can be controlled. Choose Play button to play the message. Playback number can be set. Choose Stop button to stop the playback. RM-911...
  • Page 22: Contact Setting

    UTOM TED REMOTE MESS GE 10. Contact Setting Type of the contact input can be set. Momentary : The message is played during the contact input is shorted. Switch : The message is played when the contact input is shorted and stopped when the contact input is shorted again.
  • Page 23: Time Setting

    UTOM TED REMOTE MESS GE 11. Time Setting Time zone and current time can be set. 1) Time Zone The default time zone is (GMT+09:00) Seoul. Select a correct time zone in the box according to your geographical zone. 2) Current Time Displays the current date and time.
  • Page 24: Log View

    UTOM TED REMOTE MESS GE 12. Log View This page displays the log information of the RM-911 setting and history of modification with time. If time has not been set, the log information will be shown with jan/ 1/ 1970 as default date. RM-911...
  • Page 25: Upgrade

    UTOM TED REMOTE MESS GE 13. Upgrade Down load the new firmware to your computer. Go to the system upgrade page. Choose the firmware from your computer using the ‘FIND FILE’ Tab. Start the firmware upgrade by clicking the ‘set’ button. Network settings will be retained after the upgrade.
  • Page 26: Restart

    UTOM TED REMOTE MESS GE 14. Restart To restart the RM-911, press the 'Set' button. Reboot process takes about 30 seconds. 15. Factory Setting To reset the RM-911 to factory default, press the ‘Set’ button. Reset process takes about 30 seconds. The network and time setting will be reset to default setting. RM-911...
  • Page 27: Password Setting

    UTOM TED REMOTE MESS GE 16. Password Setting Current Password – Enter the current password. New Password – Enter the new password. Password Confirm – Confirm the new password. Press the ‘Set’ button. Default password is ‘1’. Different password can be set for admin, clock and trigger. To keep security, the password have to be changed to new one before use.
  • Page 28: Pplications

    UTOM TED REMOTE MESS GE pplications pplications Telephone Local #1 Speaker Switch CD-6208 RM-911D ARM-911 RM-911D Local #2 Speaker RM-911W DPA-1200S(Amplifier) RM-911W RM-911...
  • Page 29: Block Diagram

    UTOM TED REMOTE MESS GE Block Diagram Block Diagram RM-911...
  • Page 30: Specifications

    UTOM TED REMOTE MESS GE Specifications Specifications RM-911 UX 1/2 (CH IN @1kHz) Input Sensitivity -50dBu Setting -50dBu/10kΩ ±3dB -10dBu Setting -10dBu/10kΩ ±3dB +4dBu Setting +4dBu/10kΩ ±3dB Signal to Noise Ratio (S/N, 20kHz LPF, -WTD) +10dBu Input NOR: -105dB, LIM: -100dB +4dBu Input NOR: -88dB, LIM: -80dB -10dBu Input...
  • Page 31: Dimensions

    UTOM TED REMOTE MESS GE ※ DIMENSIONS RM-911...
  • Page 32: Service

    UTOM TED REMOTE MESS GE Service Service Procedures Take steps to insure the problem is not related to operator error or other products within the system. Information provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual.

Table of Contents