Troubleshooting Guide

When Vertical Louver does not operate.

• Confirm that the Vertical Louver is normally geared with the shaft of
Stepping Motor.
• If the regular torque is detected when rotating the Vertical Louver with
hands
• Check the connecting condition of CN-UP/DOWN Connector
• Check the soldering condition(on PWB) of CN-UP/DOWN Connector
• Confirm that there is DC + 12V between pin (RED) of CN-UP/DOWN and
GND.
• Confirm that there is a soldering short at following terminals.
- Between
- Between
- Between
- Between
• Confirm the assembly conditions that are catching and interfering parts in
the rotation radial of the Vertical Louver
62 Room Air Conditioner
Normal
Check the operating circuit of the Vertical Louver
,
,
and
of MICOM
60
61
62
63
,
,
and
of IC01M
3
4
5
6
,
,
and
of IC01M
11
12
13
14
,
,
,
and
of CN-UP/DOWN
1
2
3
4
5
If there are no problems after above checks