1.
Turn the switch ON. Remember there is a fan delay.
2.
Set thermostat by turning the knob to desired room comfort level
(clockwise to increase heat output). Once you have determined
the proper setting to provide the heat level you prefer, you need not
touch the knob again.
3.
Turn the switch OFF to turn off heater. To reuse, simply turn the
switch ON - the temperature level you wish has been previously
set.
NOTE: This heater is equipped with a fan delay switch which delays
the fan operation until the heating grid has heated sufficiently to
assure the circulation of only warm air. This same switch permits
the fan to operate after power to the grid has been shut off by
thermostat action, thus utilizing all the heat remaining in the grid.
When the heater is shut down by turning the switch OFF, power to
both fan motor and element is diconnected and the fan motor will
not continue to operate.
WARNING: Should the OVERTEMP light come on, disconnect power to
the heater, turn the switch OFF or turn down the thermostat fully
counterclockwise and call a licenced electrician. DO NOT USE
HEATER UNTIL PROBLEM IS DETERMINED AND FIXED.
SPECIFICATIONS AND ORDERING INFORMATION
CATALOG No. SUPPLY VOLTS AMPS.
1.0 kW
EWA10C11
3413 BTU
EWA10C21
EWA10C31
EWA10C41
1.5 kW
EWA15C11
5122 BTU
EWA15C21
EWA15C31
EWA15C41
2.0 kW
EWA20C21
6830 BTU
EWA20C31
EWA20C41
Wall Box Opening: 14 9/16" (37cm) height, 11 1/4" (28.5cm)
width, 3 1/2" (8.5cm) depth
Front Plate: 16 3/8" (41.6cm) height, 13" (33cm) width,
extends 1 3/4" (4.5cm) from wall (recessed)
Field Installed Accessories:
8754 - Surface Mounting Box Kit
TGKSB - Tamper Proof Grille/Controls Kit
1. When installing optional wall thermostat, unit mounted thermostat must be
set at it's highest setting.
2. All external control equipment (shown with dashed lines) furnished by
customer. Control wiring must be suitable for 600V.
3. Heater branch circuits shall have a carrying capacity of no less than 125% of
maximum load served.
4. All external wiring to the heater shall be in compliance with the National
Electrical Code pr the Appliance Codes.
WALL STAT
(OPTIONAL)
THERMOSTAT
CFM
120V
8.3
50
208V
4.8
50
240V
4.2
50
277V
3.6
50
120V
12.5
50
208V
7.2
50
240V
6.2
50
277V
5.4
50
208V
9.6
50
240V
8.3
50
277V
7.2
50
Tamper Proof Models
The ON/OFF switch and the temperature regulating thermostat are
recessed so that the continuous grille front panel can be installed
concealing both controls. The thermostat is operated by removing the
front panel. The ON/OFF switch can be operated by inserting a slender
non metallic rod between grill louvers and turning the switch ON or
OFF.
Maintenance
This heater requires no maintenance other than a cleaning at least once a
year.
CAUTION: Before removing heater parts, open branch service switch
or remove fuses. These are located at the distribution panel.
To clean, remove frame, grille and heater assembly. Remove any dust
and dirt from wall box and heater assembly with a soft cloth or brush,
then re-install heater assembly making sure that the fan turns freely
and service leads are away from fan area. The frame and grille may
be washed with a mild detergent, however make sure they are thoroughly
rinsed and dried before re-installation.
SURFACE WALL
SURFACE
BOX
WOOD SCREW
BUSHING
GROUNDING
SCREW
SHEET METAL
SCREW
ELECTRICAL SERVICE PER NAMEPLATE
SWITCH
CAPACITOR
M
GRID
25" SERVICE
LEADS
REMOVE THIS
KNOCKOUT
SERVICE CABLE
Fig. 2
HEATER WALL BOX
THERMOSTAT
FAN
CONTROL
LIMIT
CONTROL
7204380100 REV04