Important Considerations
Electrical Service
A 110V, 60HZ, 15AMP GFCI protected ground must be used to supply power to each indivisual
pedicure spa. And the main circuit breaker MUST be at 25AMP for maximum of two unit.
Water Supply
All plumbing connections must conform to local codes.
Water supply to the spa should be provided with adequate water pressure and water temperature.
-Water pressure
To fill the basin correctly up to level, Normal water pressure should be between 30 to 80 P.S.I.
-Water temperature
The hot water supply temperature must not exceed 140°. Adjust your hot water accordingly. For hot
and cold water supply fittings and drain fittings location, see below diagram. Carefully connect the
water supply line to the appropriate fittings located on the rear of the pedicure spa.
Backflow Preventive Device
All pedicure spas are pre-installed with Dual Back flow Preventive Device for the following state:
CA, AZ, NV, OR, WA, and NE. This Device is optional, therefore yot need to order seperately.
Salontech does not guarantee the quality of this device.
Specification
Backflow preventive device for faucet: Vacuum breaker comply with ANSI / NSF - 61 - 2000,
ASMB A112.18.1 - 2000,
ASSE1014 and CSA standard - B125.98
ANSI / ASME A112.18.3M (performance requirements for backflow preventive device
and systems in plumbing fixture fittings) is applicable to plumbing fixture fittings with
outlets not protected by an air gap. Included in the possible range of applications are
fittings with hose connected outlets, fitting with pull out spout, hand held showers,
shampoo fittings and deck mounted fittings.
ASME A112.18.3M is now referenced in ASME A112.18.1M (plumbing fixture fittings)
and CSA B125. Backflow preventive devices are listed to both standards with the
Canadian Standard Association, IAPMO and UL.
ANSI - American National Institute. ASME - American Society of Mechanical Engineers.
CSA - Canadian Standard Association.
APMO - International Association of Plumbing and Mechanical Officials. UL -
Underwriters Laboratory.
Drain Facilities
The pedicure spa drain must meet local plumbing codes. Check valve for Drain (not
provided) Must be installed by a licensed
plumber.
Plumbing Connections
Back of the pedicure spa
1-1/2" PVC Drain Outlet
3/8" PIP Cold Water Supply Inlet
3/8" Hot Water Supply Inlet