Advertisement

----
toe p
5
n
Remove
the 4 screws attaching
access panel
and toe panel to dish-
washer
using a l/4' hex socket, nut
driver or Phillips screwdriver.
Remove
access panel
and toe panel.
6
l
Measure
height
of cabinet
opening
from the front edge of the
underside
of cabinet
opening
to floor.
Check
chart for that height
opening.
Put the wheels
in the required
position.
The dishwasher
should be installed
as
level as possible from front to back.
Loosen and then turn front levelers the
number
of times indicated
in the char-t.
34-l/18"
2
6
34-5/l 6"
3
3
34-l 12"
4
0
For addltlonal
height:
1. Add shims under the wheels.
2. Turn front levelers
(each
turn Is approximately
l/16'
In height).
You may have this type drain
connector...
7
n
Put spring-type
drain hose clamp
over connector.
Push drain hose onto
connector.
Use pliers to open clamp
and
slide clamp
over drain hose and con-
nector. Check that drain hose is secure.
If screw-type
clamp
is used instead of
spring-type
clamp,
use a 5/l 6' nut driver
to tighten
drain hose securely to
connector.
To minimize
noise and vibration,
route
drain hose to avoid contact
with door
springs, motor, water line, cabinet
or
flooring.
Do Not run drain hose over top
of tub.
Floor Damage
Tilt dishwasher
backwards
on wheels
when moving
across floor.
Failure to do so may cause damage
to floor covering.
8
w Latch dishwasher
door. Push
dishwasher
into place,
sliding drain hose
through
hole cut in cabinet
opening.
Do not pinch
power supply
cord or kink
power supply
cable
between
dishwasher
and cabinet.
Check
that front leveling
legs are firmly
against
the floor. Align dishwasher
door
with cabinet
doors, so that spacing
is
the same on both sides.
9
m Connect
drain hose to an air gap
or waste tee using one of the
recommended
or alternate
methods.
Cut hose connector
to fit, It needed.
@wJ-lm
If connecting
drain hose to an air gap
or waste tee, cut end of drain hose as
shown.
Secure drain hose with screw-type
or
spring-type
hose clamp
(clamp
type
varies with models).
Do Not cut drain hose when connecting
to a 7/8' disposer connector.
Knock out
plug from disposer
inlet. Secure drain
hose with hose clamp
provided.
DO NOT cut ribbed
section
to shorten
drain hose.
Numbers
correspond
to steps.
Recommended
drain hose
connection
methods:
Drain hose to air gap to waste tee.
alr-gap
klt (Part
No. 300096)
?
20' mlnlmum
1
spriig-
g
clearance
to
w
.ZKps
tloor
$
Entry must be
above
trap.
Drain hose to air gap to disposer.
0
ylr-gap
klt (Part No.
00096) v,
l-8
-
sprtng-
rubber connector
\
Entry must be
I
I
above
trap.
Install air gap according
to kit instructions.
If other brands
of air gaps are used, they
should be checked
to make sure they
allow for the same air flow.
Connect
the air gap to a waste tee' or
disposer using a rubber
connector*.
Most disposers have 7/8' connectors
or
special
connectors
are available
at
plumbing
supply houses. Be
sure to remove
the
disposer
plug befor
connecting
the
drain hose. You
may need to
remove
disposer
from sink to remove
the plug.
Drain hose
Panel C

Advertisement

loading