Download Print this page

Water Requirements; Drain Requirements - Whirlpool Undercounter Dishwasher Installation Instructions Manual

Undercounter dishwasher
Hide thumbs Also See for Undercounter Dishwasher:

Advertisement

power
suPPlY
cable
U.L.-llsted
straln relief
or conduit
connector
Figure 3
3. Remove
the dishwasher
terminal
box
cover.
Connect
the white and black
wires of the power
supply cable
to the
white and black leads in the terminal
box
with twist-on
wire connectors.
(See Figure
3.1
4. Loosen the front nut on
the grounding
connection
stud located
on the back of the
terminal
box. Do Not
0
loosen the rear nut on the
"-sZ:"
,,
grounding
connection
"
stud. Form the bare
grounding
wire into a U-shaped
hook.
Wrap the grounding
wire hook around
the grounding
connection
stud between
the two nuts on the stud. Securely
tighten
the front nut over the grounding
wire.
5. Check
that strain relief or conduit
connector
screws are tight. Replace
terminal
box cover.
B.
Power supply
cord method
(connecting
dishwasher
to outlet).
Local codes
may permit the use of a U-L.-
listed, flexible,
three-conductor,
power
supply cord terminated
with a three-
prong,
grounding-type
plug.
It is recommended
that cord kit (Part No.
4317824), available
at your local dealer
or parts supplier,
be used. Follow the
instructions
packaged
with the power
supply cord kit. If the cord kit is not
available
locally,
the flexible
cord used
must be a U.L.-listed, three-conductor,
1 &gauge
cord that meets the National
Electrical
Code,
ANSI/NFPA 70 -
latest
edition'
and local codes and
ordinances.
The length
of the cord must
not exceed
six feet. It must be routed
so
it does not touch
the dishwasher
motor
or the lower portion
of the dishwasher
tub. A strain relief (Part No. 596171),
available
at your local dealer
or parts
supplier,
or a similar part must be used to
secure the flexible
cord to the
dishwasher
frame or terminal
box. The
flexible
cord must be plugged
into a
mating,
3-prong,
grounding-type
wall
receptacle,
grounded
in accordance
with the National
Electrical
Code
ANSI/NFPA 70 -
latest edition,*
and all
local codes
and ordinances.
Follow the
instructions
packaged
with the flexible
cord.
Recommended
grounding
method
j-prong,
groundlng-
he
wall receptacle
,
power
supply
cord
Figure 4
For your personal
safety, this appliance
must be grounded.
A power
supply cord
having
a 3-prong
grounding
plug must
be used. It is the personal
responsibility
and obligation
of the customer
to have
a properly
grounded,
3-prong
wall
receptacle
installed
by a qualified
electriclan.
The receptacle
should be installed
on
the rear or side wall of the cabinet
next
to the dishwasher
opening.
Water
requirements
The hot water
line to the dishwasher
must provide
between
15 - 120 psi water
pressure. The hot water heater should be
set to deliver
140°F water temperature
to
the dishwasher
for best results.
Use 3/8' minlmum
0-D. copper
tubing
or
l/2' mlnlmum
plastic tubing
inlet line.
Dishwasher
inlet valve has 3/8' N.P.T.
internal
pipe thread.
Drain
requirements
^
20' mln.
to floor
The drain hose MUST have a high drain
loop, 20' minimum
ABOVE FLOOR, to
prevent
backflow
or water siphoning
out
of dishwasher
during
operation.
NOTE: An air gap MUST BE USED in
the high drain loop if the drain hose
is connected
to house plumbing
lower
than 20' above
the floor.
Drain hose, supplied,
meets AHAM DW- 1
test standards,
Cut l-l /2" hole in
cabinet
wall for drain hose. Additional
drain line (a minimum
of l/2' I.D. and no
longer than 20 feet) can be used if
needed.
Now start...
With dishwasher
in kitchen.
------I Y-
-1
cabinet
wall
--I
alternate
water-
line locatlons
water
supply
6'
pipe
4
AJ!t!$j
4'
2-l/2'
t
10'
2'
5'
1
n
Rough in water
line to the
dishwasher
cabinet
opening
using one
of the routing
methods
shown. Cut l/2'
or larger hole in cabinet
wall for
water
line.
2
n
Install a
shutoff valve
in the
water
Ilne where
it
can be easily used.
3
= Flush water
line into a bucket
to get rid of any
particles
that may clog inlet valve.
Turn
shutoff valve to the "OFF" position.
Electrical
Shock Hazard
Disconnect
electrical
power
at the
service
panel
(fuse box or circuit
breaker
box).
Failure to do so could
result in
electrical
shock or other personal
lnlurv.
electrlcal
alternate
wlrlng
electrlcal
wlrlna Iocatlon
\I?
6'
4
n
Cut a l-l /2' maximum
hole for
power
supply cord or a 3/4' hole for
direct wiring in the cabinet
or floor for
the electrical
wiring to pass through.
If
this hole is cut in a wood
cabinet,
sand
the hole until it is smooth.
If the hole is
cut in a metal cabinet,
the hole must
be covered
by a grommet
(Part No.
302797), available
at your local dealer
or parts supplier.
Install wall receptacle
on rear or side
wall of a cabinet
next to dishwasher
opening.
Install a 3/4' U. L.-listed conduit
connector
to connect
the flexible
armored
or non-metallic
sheathed,
copper
cable
(with grounding
wire) to
the fused disconnect,
circuit
breaker
or
junction
box. Run the cable
through
the
hole in the cabinet
opening.
The cable
should extend
24' from the back wall.