How To Use Test Tool - Philips DVDR3320V/01 Service Manual

Vcr+dvd recorder
Hide thumbs Also See for DVDR3320V/01:
Table of Contents

Advertisement

How to use test tool

1. ALPC Measurement System Configuration
In order to measure and adjust DVD RW optical power, The following measurement equipments are needed.
N
Compulsory equipment
➀ Optical Power meter & Sensor (ADVANTEST, TQ8210/Q82017A or equivalent
➁ Personal Computer (Pentium 3, 500MHz Above, , RAM:64M Above, Win98 Above)
➂ Adjustment Program (Dragon or ALPC) for SVC, ALPC Program recommended
N
Fl optional equipment
➀USB-ATAPI Interface (needed when using USB Port from the laptop computer without ATAPI interface or a desktop
computer)
➁Connector-ATAPI Interface Board(Part Mo:6881R-7677A) (needed when ATAPI is not attached to Loader)
USB-ATAPI Interface
Optical
Power Meter
Loader Ass'y
Personal Computer
(Desktop or Notebook)
5-43
Connector-ATAPI Interface Board

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvdr3320v/05Dvdr3320v/02Dvdr3320v/19Dvdr3320vDvdr3320v series

Table of Contents