LG LXA0810ACLY3 Service Manual page 30

Through the wall air conditioner
Table of Contents

Advertisement

• MODEL : LXA1030AXLY3 / LXA1011AHL, LXA1230AXLY3 / LXA1211AHL
2
7
NO.
DESCRIPTION
1
POWER CORD
2
ROTARY SWITCH
3
FAN MOTOR
4
CAPACITOR
5
THERMOSTAT
6
OVERLOAD PROTECTOR
7
COMPRESSOR
8
ELECTRIC HEATER
ROTARY SWITCH
8
7
6
BL
L
4
H
BK
2
1
R
COMP
S
C
RD
FUSE LINK
RD
BI-METAL
WIRING DIAGRAM
THERMOSTAT
LXA1030AXLY3
LXA1011AHL
4681A20044E
6750U-L028A
2520UKGC2DA
POWER INPUT
BK(BR)
(Plain)
GN/YL
RD
BL
BK
MOTOR
OR(BR)
YL
YL
OR(BR)
THERMOSTAT
WH
C
H
BK
L
BK
BK
RD
RD
BL
BL
BR(YL)
O.L.P
HEATER
3854AR3563D
PART NO.
2H00677U
2H00598F
6120AR2359E
2H01127D
5300A20003A
—30—
WH(BL)
(Ribbed)
CAPACITOR
F
C
C
H
LXA1230AXLY3
LXA1211AHL
4681A20041C
6750U-L058A
2520UKHK2CA
1
3
4
5
6
8
Q'TY
RE-
PER SET
MARKS
1
1
1
1
1
1
1
1

Hide quick links: