Sharp GX15 Service Manual page 48

Digital mobile phone
Hide thumbs Also See for GX15:
Table of Contents

Advertisement

GX15
3. Hold the handset (phone) in the proper position.
4. Click the "Black defect correction" button.
The following message is displayed.
5. Click the "Yes" button. Communication starts.
6. The result is displayed within a minute as follows.
When an error occurs, the corresponding message appears. Solve the problem according to "Solution".
Error 1
Error message: "There are too many black cracks."
Cause: The light is too weak or strong.
Solution: At the proper distance from the light source (8,000 - 10,000 lux), perform black defect correction again.
Error 2
Error message: "There are many black cracks."
Cause: The light is too weak or strong.
Solution: At the proper distance from the light source (8,000 - 10,000 lux), perform black defect correction again.
Error 3
Error message: "There are too many black cracks cannot be rectified."
Cause: There is a hardware error.
Solution: Replace the camera unit.
CONFIDENTIAL
Figure 76
Figure 77
Figure 78
Figure 79
2 – 40