5
1.2. Technical data
General
- Alternative voltages are stated as r.m.s. values.
- Only values with tolerances and or numerical values are guaranteed.
- Deviations (in% or ppm) apply to the adjusted value.
- Temperature
coefficients
apply within temperature
range.
- All specifications
are met after a warming-up
time of 30 minutes.
1.2.1. HF-GENERATOR
Frequency
range
0.1 MHz up to 110 MHz
9 ranges:
0.1 ...
0.3 MHz
0.3 ...
1
MHz
1
...
3
MHz
3
... 10
MHz
10
... 30
MHz
30
... BO
MHz
75
110
MHz
0.4
0.5
MHz
10.3
11.1MHz
Scale
Accuracy
Long-term stability
6
linear, illuminated
scales
<
1.5 % in the ranges 0.1 ... 80 MHz
<
1
% in range 75
110 MHz
<
0.5 %
in range 0.4
0.5
MHz
<
0.2 %
in range 10.3
11.
l
MHz
<
0.1 %
on calibrated
points
<
0.1 %
at:
~ nominal operating conditions
- mains voltage variations
+10 %, -15 %
- measured over 7 hours
Temperature
coefficient
,,;;; 5 .2.10-4;oc
Output HF OUT
Frequencv-respor se
Connection
: BNC connector
Output voltage:
50 mV into 75
~L,
at
unmodulated
signal
O.lMHz
... 110
MHz
;;;;;3c1s
0.4 MHz...
0.5 MHz (
<
0_2 dB
10.3 MHz...
11
MHz
f
;;?- 60 dB, continuous
for frequencies< 15 MHz; ;;,, 60 dB
Attenuator
1.2.2. MODULATION
Modes
unmodulated
: all ranges
AM
: all ranges
FM
: range 75 ... 110 MHz and 10.3 ... 11.1 MHz
Wobble
: ranges 75 ... 110 MHz, 0.4 ... 0.5 MHz and
10.3 ... 11.1 MHz
Modulation
frequency:
1 kHz (sine wave)
Modulation
depth
: 30 %
AM, internal

Advertisement

Table of Contents
loading