Advertisement

Quick Links

Installation Manual
NovaTec S3
Subject to change
NovaTec Kommunikationstechnik GmbH
Technologiepark 9 / DE-33100 Paderborn
Page 1 of 26
E-Mail:
info@novatec.de
Internet:
www.novatec.de
Version 2.2 / Date: Sept 2013
Phone: +49 (0)5251 1589-610
Telefax: +49 (0)5251 1589-611

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S3 and is the answer not in the manual?

Questions and answers

Summary of Contents for NovaTec S3

  • Page 1 Installation Manual NovaTec S3 Subject to change Page 1 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de Telefax: +49 (0)5251 1589-611...
  • Page 2: Table Of Contents

    4.3 Use of this Manual..........................6 4.4 Use of the Pictograms ......................... 6 The NovaTec S3 ............................ 6 5.1 Integration of the S3 ........................... 8 5.2 ISDN over IP ............................9 5.3 Creating an ISDN resp. analogue Interface .................. 11 5.4 Synchronous Data Transfer ......................
  • Page 3: Introduction

    In case that an internal component is obviously damaged, e.g. because of a damaged housing, please remove the S3 from the power supply immediately. In order to avoid material damage or injury to persons, never expose the S3 to water (rain) or exces- sive moisture.
  • Page 4: Declaration Of Conformity

    Declaration of Conformity Subject to change Page 4 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de Telefax: +49 (0)5251 1589-611...
  • Page 5: General

    General 4.1 Product Description The S3 Gateway provides a connection between IP networks (SIP protocol) and ISDN networks resp. ana- logue terminal equipment. The S3 has an IP-interface with codecs for four B-channels and depending on the version also ISDN, BRI, U 0 (point-to-point) and analogue a/b interfaces.
  • Page 6: Use Of This Manual

    This manual is devided into single chapters. The succession and the contents of the different chapters coincide with the succession of the tasks necessary for the installation and initializing of the S3. We there- fore suggest reading the manual in its successive chapters as they are written, executing the tasks suc- cessfully before moving on to another chapter.
  • Page 7 *GPS antennas are no longer used. Alternatives are the type 1F8000RQ or the use of a RMCS server. Subject to change Page 7 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610...
  • Page 8: Integration Of The S3

    5.1 Integration of the S3 The S3 was developed to be embedded in existing networks in which interfaces are to be converted. The S3 is versatile and the version selected depends on the field of application. Picture 2 shows an overview of possible fields of applications of all versions. Please check Table 1 in addi- tion as well.
  • Page 9: Isdn Over Ip

    (for connecting telecommunication systems or for cross connecting trunk lines). Thus the S3 can also be used to isolate a system via IP network. The following pictures show examples for this. The ISDN features are transparently passed through and are entirely available on both sides if NLP (Novatec Link Protocol) ist used..
  • Page 10 Picture 5: Example of an application of a telecommunication network via IP Subject to change Page 10 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de...
  • Page 11: Creating An Isdn Resp. Analogue Interface

    5.3 Creating an ISDN resp. analogue Interface The S3 can provide an analogue interface for analogue terminal equipment respectively an ISDN interface (S0- resp. UP0) for ISDN terminal equipment or for the connection of ISDN trunk lines from a single SIP string.
  • Page 12: Synchronous Data Transfer

    The latter is only required with mobile phones or similar end devices which depend on minimum accuracy of the given clock pulse. The S3 comes with 4 codecs for VoIP, two BRI interfaces and can be used for clock pulse synchronization via RMCS. For a synchronous data transfer between several locations a RMCS Server, which has to be connected with each and every system which is to be synchronized, is additionally required.
  • Page 13: Delivery Status

    The current firmware version can be downloaded from www.novatec.de > Downloads. The firmware license for the current firmware is delivered by email as soon as the S3 is dispatched. 6.1 Factory Set-Up DHCP with option 129 is activated in the factory set-up.
  • Page 14: Reset Into Default Configuration

    „nopassword“). A new license key is only needed if the firmware version is to be updated. Parallel to the dispatch of the S3 you will receive the license data via email. Store the license key well: Subsequent deliveries are with...
  • Page 15 A configuration data base file is created (mdb) with the users interface which is created from the configu- ration surface and then stored on the computer. After this is done connect the computer to the S3 via USB or Ethernet (cross-over wire).
  • Page 16: Firmware Update Via Trace Info Client (With Usb Or V.24)

    If the S3 is in default mode after the restart the data base file was damaged. The LED`s in the system show the operational condition of the system. Should the system be in default mode please reconnect the S3 with the computer and correct the configuration before transferring the altered data base file onto the S3.
  • Page 17 Windows board tools or the function “close and copy to file” in the configuration mask under the menu topic “File”. Subject to change Page 17 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de...
  • Page 18: How To Upload The Firmware License Into The Configuration

    Even though the transmission time is prolonged with this choice it is important when logging into the S3 system from a remote PC that Subject to change Page 18 of 26 Version 2.2 / Date: Sept 2013...
  • Page 19 You can give each system a name enabling you to differ e.g. the system configurations better. If a system does not have a name please leave the entry box empty. Subject to change Page 19 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de...
  • Page 20: Installation

    After its configuration the S3 can be installed at its destination with plug-and-play. Without prior configura- tion the S3 has its default IP address and hence is possibly outside remote reach within your IP net. Please pay special attention when designating your IP addresses of routers and firewalls.
  • Page 21 Picture 14: BRI interface cross connection system termination (extended passive bus) Subject to change Page 21 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de...
  • Page 22: Status Display

    7.5 Status display The status display of the S3 is divided into two categories: The boot stage (picture 16) and the operational stage. Several test steps are run during the boot stage which can be partially followed by watching the LEDs.
  • Page 23 Picture 16: Status indication of the S3 Subject to change Page 23 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de Telefax: +49 (0)5251 1589-611...
  • Page 24: Signal Assignment Of The Interfaces

    7.6 Signal assignment of the interfaces Picture 17: Signal assignment of the interfaces Subject to change Page 24 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de...
  • Page 25: Technical Data

     Worst Case and guaranteed: +/- 5 ppm (5 * 10-6) Subject to change Page 25 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de Phone: +49 (0)5251 1589-610 Technologiepark 9 / DE-33100 Paderborn Internet: www.novatec.de...
  • Page 26: E-Mail: Info@Novatec.de

    0% to 95% relative humidity (not condensing) Heat Loss 30 J Max./Min. Temperature 0 to 40° C ® *not available with TransNova S3 (Cisco VG2-BRI-R) Subject to change Page 26 of 26 Version 2.2 / Date: Sept 2013 NovaTec Kommunikationstechnik GmbH E-Mail: info@novatec.de...

Table of Contents