Download Print this page

Keating Of Chicago UA Flame Master Lo-Temp Griddle Service Instructions

Flame master lo-temp griddle control

Advertisement

Quick Links

S E R V I C E I N S T R U C T I O N S
www.keatingofchicago.com
FLAME MASTER® LO-TEMP GRIDDLE CONTROL
Model UA Flame Master® consists of a gas griddle control and automatic shut-off valve with No. 70
pilot burner, Temperature range–"BROIL" down to 140°F.
SELECT-A-GAS
PILOT ADJUSTOR
GASKET
INLET FITTING
MOUNTING FLANGE
LIGHTING INSTRUCTIONS
1. Be sure temperature dial is in "OFF" position.
2. Turn "ON" main gas supply to appliance.
3. With SELECT-A- GAS PILOT ADJUSTOR in
"open" position, (turn ADJUSTOR full clockwise
for natural gas or full counter clockwise for LP
gas) "LIGHT" standby pilot. (See Figure 2).
4. To light GRIDDLE BURNER–turn temperature
dial counterclockwise to desired temperature
setting.
GRIDDLE BURNER WILL IGNITE ABOUT 45
SECONDS AFTER DIAL IS TURNED TO
DESIRE TEMPERATURE SETTING.
TOP BURNER
PILOT ADJUSTOR
CALIBRATION
PLATE AND MARKS
CALIBRATION
SCREW
GRIDDLE TEMPERA-
TURE
"D"STEM
(SHOWN AT APPROX.
450 DIAL SETTING)
BEZEL
No. 70
PILOT BURNER
MSC SHUT-OFF
VALVE
1-800-KEATING
FIGURE 1
TEMPERATURE
DIAL
"LIGHT"
(STANDBY PILOT)
70
TEMPERATURE
RESPONSIVE
BULB
FIGURE 2
Lotempoc
4-96