TABLE OF CONTENTS Introduction...2 Controller Key Descriptions ...3 Operating the Controller...4-5 Display Descriptions ...6 Controller Features ...7 Programming the Controller...8-13 Customer Support and Other Information...15 INTRODUCTION Thank you for your purchase. You have chosen a product with over 25 years of innovation and quality manufac- turing behind it.
CONTROLLER KEY DESCRIPTIONS When lit (bright) indicates that a product hold time is being tracked. IM-2000 ™ Optional “soft” ON/ OFF key switches controller functions off while leaving power to the appliance on. In “operating” mode, allows access to the pro- gramming mode.
OPERATING THE CONTROLLER Starting a Cook Cycle To start a cook cycle, simply press the product key for the product you wish to cook. If the product key is programmed, the correct cooking time will be displayed to count down in minutes and seconds. The pressure solenoid will also close if programmed to do so. If is displayed immediately and the unit starts to signal, the key being operated is not programmed.
CAUTION: PLEASE CONSULT AND FOLLOW KEATING’S GUIDELINES FOR CLEANING AND BOILING OF THE FRY VATS. The boil function accurately maintains the fryer temperature at 190°F (88°C) to assist in the cleaning of fry vats. To start the boil process, turn the appliance OFF. Empty the fry vat of shortening. Once the vat is emptied of shortening and refilled with cold water, the controller and fryer may now go into boil.
The unit is in Fahrenheit or Celsius Programming mode. The unit is in Controller Backup Programming mode. The unit is in Fryer Preheat or Melt Cycle Programming mode. The unit is in the Appliance Type Programming mode. NOTE: Not all features are available on all models.
CONTROLLER FEATURES Fahrenheit or Celsius Temperature Display The operator will have the ability to configure the controller to display the temperature in degrees Fahrenheit or Celsius from the System Programming mode. Melt Cycle When the computer is ON and the vat temperature is below the Melt Limit Temperature, the controller will control the melting of the shortening.
PROGRAMMING THE CONTROLLER PROGRAMMING NOTES: 16 button units have 2 displays that show a full line of information; for example: 8 button units have a single, dual-purpose display that will alternate information; for example: (and then) SCAN advances you to the next setting for the same function. ENTER completes programming for that function and advances you to the next function.
Page 9
PROGRAMMING THE CONTROLLER Programming Flex or Straight Time Operation Press Display to toggle between choices (See note below before continuing.) Programming Action Alarm Times Press Display THE UNAUTHORIZED USE OR DUPLICATION OF THE SOFTWARE DESCRIBED HEREIN, OR THIS MATERIAL IS STRICTLY PROHIBITED. Flex or straight time option is now entered.
PROGRAMMING THE CONTROLLER Programming Hold Times Press Display NOTE: Up to 4 hold timers can be programmed per product key on the 8 button controller; up to 8 hold timers can be programmed per product key on the 16 button controller. Programming Cook Temperature Press Display...
PROGRAMMING THE CONTROLLER Entering System Programming Mode Press Display • The controller is now in System Programming Standby Mode. Programming Fahrenheit or Celsius Temperature Display Press Display current degree option is displayed Programming Operating Mode (Controller or Timer) Press Display toggle between Controller...
Page 12
Press Display current toggle appliance between three appliance configurations type is for size of fryer or power type; for displayed example: ELEC — Electric Fryer GAS — Gas Fryer GEN — Generic Option Selected* *This display may differ depending on custom configuration of the controller.
PROGRAMMING THE CONTROLLER Exiting System Programming Press Display The controller is now in Operating Standby Mode. THE UNAUTHORIZED USE OR DUPLICATION OF THE SOFTWARE DESCRIBED HEREIN, OR THIS MATERIAL IS STRICTLY PROHIBITED. One of these displays will appear. IM-2000 ™...
Page 14
NOTES NOTE: Not all features are available on all models. NOTE: Not all features are available on all models. THE UNAUTHORIZED USE OR DUPLICATION OF THE SOFTWARE DESCRIBED HEREIN, OR THIS MATERIAL IS STRICTLY PROHIBITED.
Warranty Statement Keating of Chicago, Inc. provides a limited one-year warranty for its products (except probes and hoses for which the period is 90 days). A copy of the exact provisions of this warranty and the other terms and conditions of sale are available upon request.
Page 17
IM-2000 Literature Part #229-51017 Rev. A ™ KEATING OF CHICAGO, INC. 8901 W. 50th Street, McCook, Illinois 60525-6001 Phone: (708) 246-3000 FAX: (708) 246-3100 Toll Free 1-800-KEATING (In U.S. and Canada) www.keatingofchicago.com THE AUTHORIZED USE OR DUPLICATION OF THE SOFTWARE HEREIN, OR THIS MATERIAL, IS STRICTLY PROHIBITED.