TECHNICAL MANUAL
The Buxton
Multifuel Stove
Model BX1MF
To be retained by the user for future reference
Serial Number ..................................
Document BX1MF 0101
Version 1Date 17/10/2013
Thank you for purchasing an ACR Heat Products stove.

Advertisement

loading

Summary of Contents for ACR Electronics The Buxton BX1MF

  • Page 1 TECHNICAL MANUAL The Buxton Multifuel Stove Model BX1MF To be retained by the user for future reference Serial Number ……………………………. Document BX1MF 0101 Version 1Date 17/10/2013 Thank you for purchasing an ACR Heat Products stove.
  • Page 2  The appliance must not be modified in anyway unless authorized by ACR Heat Products Ltd.  The appliance should be inspected regularly to ensure the airways are clean and free from obstruction and the chimney swept at least once a year.
  • Page 3 BUXTON SPECIFICATIONS Nominal heat output ………… 7.2 kW – WOOD 7.5 kW – SMOKELESS FUEL Chimney draft required ……… 12Pa Height …………………………… 595 mm Width ……………………………. 542 mm Depth …………………………..415 mm Weight …………………………… 80 kg Direct Air Intake………………… 80mm Air Requirement ………………..
  • Page 4 Buxton Dimensions...
  • Page 5 The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area.
  • Page 6: Installation Instructions

    Installation Instructions CO Alarms It is required by building regulations that whenever a new or replacement wood/solid fuel or biomass appliance is installed in a dwelling a carbon monoxide alarm to BS EN 50292:2002 must be fitted in the same room as the appliance.
  • Page 7 Hearth Requirements The appliance must stand on a level fireproof hearth with a minimum thickness of 12mm. The hearth temperature created by this stove is below 100˚C. The hearth must protrude at least 300mm in front of the appliance and 150mm either side of the appliance. The appliance shall be installed on a floor with an adequate load bearing capacity.
  • Page 8: Assembly Of The Unit

    Assembly of the unit If this unit is to be installed in a smoke controlled area the manufactures permanent stop must be fitted to the secondary air control in all circumstances. To install the smoke exemption square, Firstly fully open the secondary slider by pushing the handle fully to the right Insert the square into the far left of the secondary channel and tap into place using a hammer or other suitable tool...
  • Page 9 Maintenance The chimney should be swept at least once a year together with the flue pipe connection. Care should be taken to ensure that there is not a build up of soot on the baffle and in the airways of the appliance. If the appliance has not been operated for long periods, the flue should be inspected and swept before use to ensure there are no blockages within the flue.
  • Page 10: User Instructions

    User Instructions Please note that during the first firing, we recommend a small fire is lit and that you slowly increase the temperature to enable the various parts to expand normally. You may also experience fumes and a haze being given off by the stove during the first firing and possibly for the next couple of firings as the paint cures.
  • Page 11 Instructions for use with wood  Slide the top air control to the right and pull open the primary air fully.  Lay firelighters or rolled up newspapers on the grate and add a small amount of kindling wood to the top. Place 1 or 2 small logs on the top. ...
  • Page 12 Never overload the stove – it will work very well with two medium sized logs. The amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke. Operation with door left open Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open except as directed in the instructions.
  • Page 13 Troubleshooting Problem Probable Cause Action Recommended Fire difficult to Green wood / wet wood Use hardwood logs Start / Fire goes with a maximum moisture content of 20% Logs are too large Use small logs to start The fire and once Established use split logs Not enough primary air Open air control...
  • Page 17: Spare Part List

    SPAREPART LIST STOVE-K4301 BUXTON Position Quantity Description Fireplace number burning chamber door complete 8400-315 hinge 5136-414 flue spigot 3490-047 flue spigot gasket (8x3) 1982-004 9900-1258B airbox cover cap 3811-551A heat protection plate 4811-305B distance piece 7922-011 primary air regulator 5311-588B linea spring 6536-018 door cover plate...
  • Page 18 Commissioning Check List (Please mark box when completed) Ensure the serial number has been recorded on the front of this manual for any future use Ensure the door seals are in good condition and that the glass is secured correctly in the door (do not over tighten the glass as this will prohibit its expansion and could cause the glass to crack) Ensure that all internal components are fitted correctly (these may have shifted in transit)
  • Page 19  Baffle plates Your statutory rights are not affected by this warranty. In the event of a warranty claim, please return the form overleaf to ACR Heat Products Ltd, Unit One, Weston Works, Weston Lane, Tyseley, Birmingham, B11 3RP, UK.
  • Page 20 Warranty Claim Form Customer Name: ……………………………………………………………………… Customer Address: ……………………………………………………………………. ……………………………………………………………………………………………… ……………………………………………………………. Postcode …………………. Daytime Tel: ……………………………. Mobile Tel: ……………………………… Model Name: …………………………… Model Number: ………………………. Serial Number: …………………………………………………………………………. Date of purchase: …………………………………………………………………….. Date of installation: …………………………………………………………………… Installer’s Name and address: ……………………………………………………… ………………………………………………………………………………………………...