The manual control is used to activate the door Model H is equipped with a chain hoist to aid in manual operation. Use of this feature will not affect the limit switch adjustment.
PREPARATION shipping carton, inspect the nameplate on WARNING the cover of the operator control box to verify that it is the correct model for the ELECTRIC DOOR OPENERS ARE DESIGNED FOR intended application and that the voltage DOORS GOOD WORKING CONDITION, and phase are in accordance with electrical PROPERLY COUNTERBALANCED AND PROPERLY...
Reinforcement Kit. the floor and; • PowerMaster Models H and J are Commercial c) away from all moving parts of the Vehicular Door Operators and as such are NOT door.
Page 6
INSTALLATION INSTRUCTIONS SPRINGS, PULLEYS, CABLES AND MOUNTING HARDWARE USED TO BALANCE YOUR GARAGE DOOR ARE UNDER EXTREME TENSION AT ALL TIMES AND CAN CAUSE SEVERE INJURY OR DEATH IF DISTURBED. WARNING DO NOT ATTEMPT ADJUSTMENT. Page 8 illustrates several positions suitable for positions on the shafts if necessary and tighten mounting the operator;...
Page 7
INSTALLATION INSTRUCTIONS CHAIN HOIST INSTALLATION 1. If the operator is furnished with a chain Hoist (Model H)Refer to Figure 5 to install the chain hoist. Pass the hand chain, item 13 over the chain pocket wheel and through the guide holes in the chain guard. Fasten...
Page 8
DOOR TYPES & MOUNTING POSITIONS Figure 6 #1 Vertical Front of Coil, Right Hand #2 Horizontal Top Of Coil, Right Hand #3 Vertical Wall Mount, Right Hand #4 Horizontal Side of Coil, Right Hand #5 Horizontal Front of Coil, Right Hand #6 Vertical Front of Coil, Left Hand #7 Horizontal Top Of Coil, Left Hand #8 Vertical Wall Mount, Left Hand...
INSTALLATION INSTRUCTIONS engages the Open Limit Switch, the switch will sound WARNING an audible “click” when engaged. If the Open Limit is a DPDT switch (a total of 6 (six) connecting terminals protruding from the switch body, a SPDT switch has TO AVOID RISK OF ENTRAPMENT AND POSSIBLE only three (3) terminals), you will need to listen for two DAMAGE TO THE DOOR AND OPERATOR THE LIMITS...
115 Volts AC to 480 Volts AC, in electrical conduit. single or three phase. Check the operator Note: Most H & J operators are pre-wired to nameplate label on the control box cover for accept reversing edge components. To comply the proper voltage and phase. The application...
Page 12
PNEUMATIC DOOR EDGE INSTALLATION - FIELD WIRING Figure 16 Figure 9 PHOTOCELL OR 3-WIRE AIRSWITCH SINGLE TIMER DEFEAT EXT'L INTL'K CONTACT SWITCH (N.C.) (WHEN REQ'D) CONTROL (WHEN REQ'D) 2-WIRE EDGE OR AIRSWITCH OBSTRUCTION (SEE NOTE #3) SENSING DEVICE NOTES: - INSTALL BROWN JU MPER W IRE IF TH ERE IS NO STOP BUTTON OR EXTERNAL INTERLOCK SW ITCH CONNECTED TO TER MINAL STRIP.
OPERATION AND ADJUSTMENT INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS FOR OWNER TO REDUCE THE RISK OF SEVERE INJURY OR WARNING DEATH: READ AND FOLLOW ALL INSTRUCTIONS! • NEVER let children operate or play with door controls. Keep the Remote Control away from children.
OPERATION AND ADJUSTMENT INSTRUCTIONS CLUTCH ADJUSTMENT Due to changing conditions of the door and WARNING normal wear, it may be necessary to occasionally readjust clutch obtain dependable operation. RISK OF ENTRAPMENT THAT MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH. WARNING: BEFORE DOING SO BE CERTAIN DISCONNECT POWER TO THE OPENER...
Likewise, it should fully clear the door opening without the carrier striking the stops on the rail. Model H & J operators are equipped with a reversing edge circuit for use with pneumatic edge or foam edge door components.
MAINTENANCE Normally, very little maintenance is required. A monthly visual inspection must be made for loose or missing hardware and for excessive slack in the v-belt and jackshaft chain. The clutch must be checked periodically and adjustments made if necessary. (See page 14) WARNING DO NOT STAND UNDER DOOR TO TEST REVERSING EDGE.
Page 17
OPERATION AND ADJUSTMENT INSTRUCTIONS SYMPTOM POSSIBLE CAUSE SOLUTION Motor runs but Door jammed or obstructed. Check manual operation of door. door does not Sprocket key missiing or drive Check drive chain for operation. move chain broken. Limit switches do Drive chain too loose; permits Adjust chain to proper tension.
WIRING DIAGRAM NO. 331-3 ETC. MAY BE CONNECTED TO TERMINALS INDICATED. SENSING DEVICE Copyright PowerMaster 1997 B-REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC UNITS). PULL SWITCHES No portion of this diagram may be reproduced without the expressed written permission of the manufacturer.
WIRING DIAGRAM NO. 333-3 B-REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC UNITS). PULL SWITCHES AND SINGLE CONTACT CONTROL STATIONS, Copyright PowerMaster 1997 No portion of this diagram may be reproduced without the MAY BE CONNECTED TO TERMINALS INDICATED. expressed written permission of the manufacturer.
WIRING DIAGRAM NO. 1331-3 SENSING DEVICE ETC. MAY BE CONNECTED TO TERMINALS INDICATED. Copyright PowerMaster 1997 B-REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC UNITS). PULL No portion of this diagram may be reproduced without the SWITCHES AND SINGLE CONTACT CONTROL STATIONS, MAY BE CONNECTED TO TERMINALS INDICATED.
ETC.. MAY BE CONNECTED TO TERMINALS INDICATED. WIRING DIAGRAM 1333-3 B-REMOTE CONTROL UNITS (EXCLUDING TREADLES AND PHOTO-ELECTRIC Copyright PowerMaster 1997 UNITS). PULL SWITCHES AND SINGLE CONTACT CONTROL STATIONS, No portion of this diagram may be reproduced without the MAY BE CONNECTED TO TERMINALS INDICATED.
PowerMaster Limited 2 Year Warranty PowerMaster warrants all door operators to be free of defects in materials and workmanship for a period of two (2) years from date of purchase. If any part is found to be defective during this period, new parts will be fur- nished free of charge.
Page 23
Call 1- 800 - 323 - 3674 to order or to find a distributor near you Standard Two Year Warranty Warehouses across the country w/ factory trained managers Prompt delivery from stock 06-0922 H-J Special operators normally ship within 7 days...