This manual replaces RS2410001 Rev. 4
Service Manual for
Amana 
Caloric 
Modern Maid 
This manual is to be used by qualified appliance
technicians only. Maytag does not assume any
responsibility for property damage or personal
injury for improper service procedures done by
an unqualified person.
Models and manufacturing
numbers in this manual
AKO2000
P1142512N
AKS30
P1142501N
AKS3020*
P1142517N
AKS3030*
P1142527N
AKS3030*
PAKS3030*
AKS3040*
P1142513N
AKS3040*
P1142518N
AKS3040*
P1142522N
AKS3040*
P1142525N
AKS3040*
PAKS3040*
AKS3050*
P1142526N
CKS3020*
P1142515N
GT341
GT451
GT583
KGT341
P1123230N
KGT341
P1131428N
PGT120U
P1142504N
PGT153U
P1142506N
RTP201
P1131401N
RTP203
RTP300
RTP302
RTP304
RTP305
RTP306
P1142508N
RTP306U
P1131494N
RTP307
RTP308U
P1142505N
RTP348
RTP349
16021879
Revision 0
August 2002

Advertisement

Table of Contents
loading

Summary of Contents for Maytag GT341

  • Page 1 RTP307 RTP308U P1142505N RTP348 RTP349 This manual is to be used by qualified appliance technicians only. Maytag does not assume any responsibility for property damage or personal injury for improper service procedures done by an unqualified person. 16021879 Revision 0...
  • Page 2: Important Information

    CAIR Center Web Site Telephone Number W W W .AMANA.COM ........1-800-843-0304 W W W .JENNAIR.COM ........1-800-536-6247 W W W .MAYTAG.COM........1-800-688-9900 CAIR Center in Canada ....... 1-800-688-2002 Amana Canada Product ........ 1-866-587-2002 Recognize Safety Symbols, Words, and Labels DANGER DANGERImmediate hazards which WILL result in severe personal injury or death.
  • Page 3: Table Of Contents

    Clearances............12 AKO2000 ..............21 Above a Drawer ..........12 AKS30, PGT153, and RTP308......22 Placing Unit in Countertop ........ 12 GT341 / PGT120 ..........23 Adjusting Top Pilots (Gas Ignition) ....12 GT451..............24 Automatic Pilotless Ignition Models ....12 GT583..............25 RTP306 and RTP307 ...........26 AKS3020, AKS3030, AKS3040, AKS3050, and CKS3020 ............27...
  • Page 4: General Information

    T-Radiant Smoothtop (3.3 cu. ft. oven) H-Halogen Smoothtop Wall oven ⋅27DG=27” Double Gas Wall oven, 1 Dual 2T-Radiant (Two 3.3 cu. ft. ovens) Element Smoothtop Wall oven or Cooktop, 1 Dual Element 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 5: Modern Maid Cooking Products Nomenclature

    21” RTP305 Pilot 29-1/2” 21” RTP306 Spark 29-1/2” 21” RTP307 Spark 29-1/2” 21” RTP308 Spark 29-1/2” 21” Refer to Rating Label on above models for information on Natural/L.P. gas supply pressure. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 6: Before Installing

    A qualified electrician should check any receptacle the customer doubts is properly grounded. The wiring diagram is on the bottom of the cooktop. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 7: Pressure Testing The Gas Supply Piping System

    LP NOTE: Some models may not have washers. If washer use is explained and illustrated in the following is not supplied, none is needed. examples. Spring L.P. Gas Natural Gas 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 8: Example Four

    Do not overtighten orifice hood. Damage to pins inside 4. Reinstall spring and washer. the orifice hoods may result if hoods are overtightened. 5. Tighten cap. Washer L.P. Gas Natural Gas 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 9: Burner Section - All Models

    For the best results, each burner should display a proper Min. width 30" flame. A proper flame has a blue-green inner core, a dark blue outer mantle and a soft appearance. 1-3/8" 27-5/8" 20" 13-3/4" 1-1/2" 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 10: Clearances

    • Side by side cooktops - 5-7/8 inches, measured from the side flanges of the maintops. • Rear wall - 1-3/8 inches • Right side wall - 1/4 inch High • Left side wall - 5-7/8 inches Flame 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 11: Installation Notes Rtp201 And Rtp203 Models

    There must be enough clearance to accommodate the pressure regulator and Flash Tube make adjusting the regulator easier. Pilot Flame Pilot Adjustment Screw 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 12: Installation Notes Rtp302, Rtp304, Rtp305, Rtp306 And Rtp307 Models

    Turn the knob to the “HI” position after burner lights. The electrode will stop sparking. There are no standing pilots to light or adjust. Models with ignitor coils operate similarly except the ignitor coil will glow. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 13: Installation Notes Aks3020, Aks3030, Aks3040, Aks3050, And Cks3020

    Adjusting • If flame is blowing or noisy, close air shutter. Tinnerman to burner box. screw 5. Reassemble in reverse order. 6. After adjustment retest burner flames. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 14: Operating Instructions

    Do not use pans that exceed the diameter of the burner. Typical Control Knob 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 15: Top Burner Settings

    Call Amana Consumer Affairs for a recommendation. Shaft WARNING The flame should not extend beyond the edge of the cooking utensil. It may contact clothing or pot holders and cause a fire. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 16: Sealed Burners

    Water logged burner parts might cause uneven heating or interfere with automatic lighting. Flame Port Holes/Slots Ignitor Slot Ports Ignition Burner Body Port Holes Cleaning Sealed Burners Flashing Tube Cleaning Open Head Burners 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 17: Troubleshooting Procedures

    • Clean ceramic, check grounding adjustment. strap spark gap according to information in the following section. Top Burner Valve Tri-Set burner valves are standard for all models except RTP203, and RTP201. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 18: Spark Module (Models Rtp306 And Rtp307)

    Repeat same procedure with the other ignitor lead. No continuity on either lead indicates an open circuit in the ignitor lead wire. Replace ignitor lead. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 19: Disassembly Procedures

    2. Remove grates, maintop and burners. bottom rear of the assembly. 3. Remove actuator switch assembly on applicable models. 4. Unscrew valve from manifold. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 20: Spark Module Removal

    4. Remove screws securing spark module to burner box. 5. Disconnect lead wires to spark module and remove. 6. Reverse procedure to reinstall. When installing spark module verify that lead wires are correctly connected to unit. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 21: Wiring Diagrams And Schematics

    SF2 is SEW-2/SF2 200 C rated Spark Module Circuit for AKO2000 2. See serial plate for input ratings. Part Number 35-315140-04-0 3. All replacement wires must have same ratings as original wires. 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 22: Aks30, Pgt153, And Rtp308

    All wires 18 GA, 150 C, X-Linked, Except where noted. WIRING DIAGRAM Electirc Ignitor Circuit for AKS30, PGT153, and RTP308 Electric Ignitor Circuit for AKS30, PGT153, and RPT308 Part Number 35-308249-04-0 Part Number 35-308249-04-0 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 23: Gt341 / Pgt120

    To avoid risk of electrical shock, personal injury, or death, disconnect power to cooktop before servicing, unless testing requires it. Switches Ignitor SCHEMATIC Supply Cord Disconnect Spark Module Switches Electrode GA Type Code Color White WIRING DIAGRAM Spark Module Circuit for GT341 / PGT120 Part Number 81-05-483 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 24: Gt451

    Module SCHEMATIC Supply Cord Disconnect 1 2 3 1 2 3 Switches Spark Module Electrodes Code Color GA Type Blue White WIRING DIAGRAM Spark Module Circuit for GT451 Part Number 35-042914-04-0 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 25: Gt583

    Valve Switches Spark Module SCHEMATIC Valve Switches Disconnect Electrodes Spark Module Power Cord GA Type Code Color Blue WIRING DIAGRAM White Spark Module Circuit for GT583 Part Number 81-05-577 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 26: Rtp306 And Rtp307

    120 VAC Spark Ignitors Front Rear Spark Module Micro Switches Thermoset WIRING DIAGRAM Spark Module Circuit for RPT306 and RPT307 Part Number 69628 16021879 Rev. 0 2 002 Maytag Appliances Company ©...
  • Page 27: Aks3020, Aks3030, Aks3040, Aks3050,

    Electrodes SCHEMATIC Connector Connector Spark Module 22 GA HI Voltage 250 C Manifold Surface Switches Electrodes WIRING DIAGRAM Electric Ignitor Circuit for AKS3020, AKS3030, AKS3040, AKS3050, and CKS3020 Part Number 35-317134-05-0 16021879 Rev. 0 2 002 Maytag Appliances Company ©...