Separation Roller - Konica Minolta DF-502 Service Manual

Table of Contents

Advertisement

Field Service Ver. 1.0 Apr. 2005
2.1.2

Separation Roller

4688D023AA
4688D024AA
4688D025AA
4688D026AA
2. Periodical check
A. Replacing Procedure
1. Open the Upper Door.
2. Remove two screws and the Separa-
tor Section Protective Cover.
3. Unhook one spring and remove the
Separation Roller Assy.
4. Remove the Separation Roller.
B. Cleaning Procedure
1. Remove the Separator Section Pro-
tective Cover.
2. Using a soft cloth dampened with
alcohol, wipe the Separation Roller
clean of dirt.