Auscrown Y018LPWF Installation & Operating Instructions Manual

Duckbill stockpot burner with flame failure safety device

Advertisement

Quick Links

Revision 2 November 2012
DUCKBILL STOCKPOT BURNER
WITH FLAME FAILURE SAFETY DEVICE
INSTALLATION & OPERATING INSTRUCTIONS
Not to be installed for domestic use, commercial use only
MODELS: Y018LPWF, Y018NGWF, Y028LPWF & Y028NGWF
The appliance should be installed in accordance with the requirements of
AS/NZS5601.1 and the following:
 Local installation codes for gas building equipment;
 Manufacturer's installation instructions;
 Local gas fitting regulations;
 Municipal building codes; and any other relevant statutory regulation.
TO BE INSTALLED BY AN AUTHORIZED PERSON
The appliance must be:
Installed, serviced and removed by an authorised person only.
It is the operator's responsibility to see that the burner is properly assembled and maintained.
Failure to follow instructions in this manual could result in physical injury and/or property damage.
HAZARDOUS FIRE OR EXPLOSION MAY RESULT IF INSTRUCTIONS ARE IGNORED.

FOR YOUR SAFETY

IF YOU SMELL GAS:
TURN OFF MAIN GAS SUPPLY IMMEDIATELY
EXTINGUISH ALL NAKED FLAMES AND DO
NOT OPERATE ANY ELECTRICAL
APPLIANCES NEAR THIS APPLIANCE
VENTILATE THE AREA WELL
CHECK FOR LEAKS AS DETAILED IN THIS
MANUAL
IF ODOUR PERSISTS, CONTACT PLACE OF
PURCHASE OR GAS SUPPLIER
IMMEDIATELY
PLEASE READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING AND IT IS
RECOMMENDED THAT THIS MANUAL BE RETAINED FOR FUTURE REFERENCE.
FOR USE WITH NATURAL AND PROPANE GAS ONLY
WARNING
Testing for gas leaks must be checked before the
appliance is used especially following
disconnection and reconnection of the cylinder
NEVER CHECK FOR LEAKS WITH A MATCH OR OPEN
FLAME
DO NOT STORE OR USE PETROLEUM PRODUCTS OR
OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE
VICINITY OF THIS APPLIANCE
AN LP CYLINDER NOT CONNECTED FOR USE IN THIS
APPLIANCE SHALL NOT BE STORED NEAR THIS
APPLIANCE
TO BE INSTALLED ON A FIREPROOF BASE ONLY
PRECAUTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Y018LPWF and is the answer not in the manual?

Questions and answers

Summary of Contents for Auscrown Y018LPWF

  • Page 1: For Your Safety

    WITH FLAME FAILURE SAFETY DEVICE INSTALLATION & OPERATING INSTRUCTIONS Not to be installed for domestic use, commercial use only MODELS: Y018LPWF, Y018NGWF, Y028LPWF & Y028NGWF The appliance should be installed in accordance with the requirements of AS/NZS5601.1 and the following: ...
  • Page 2 Revision 2 November 2012 IMPORTANT  Read the following instructions carefully and be sure your appliance is properly installed, assembled and cared for. Failure to follow these instructions may result in serious bodily injury and/or property damage.  This appliance is intended for commercial use only. ...
  • Page 3 Revision 2 November 2012 PROCEDURES FOR GAS LEAKAGE The strong and distinctive odour of gas may make you aware of a gas leak. If you suspect a gas leak:  Immediately turn off the main gas supply.  Turn off all appliances and pilot lights; ...
  • Page 4 Revision 2 November 2012 PREPARE TO ASSEMBLE THE APPLIANCE Check for damage on the appliance. If damage occurs, please contact Austcrown or your dealer. Do not use a damaged appliance. WARNING! It may hazardous to attempt to use a damaged appliance. Positioning the Appliance Only use the appliance in well ventilated areas.
  • Page 5 Revision 2 November 2012 EXAMPLE 2 EXAMPLE 3 EXAMPLE 4...
  • Page 6 The Gas Inlet is located for model Y028NGWF/Y028LPWF 300mm up from the base and 25mm in from the RH side leg. For model Y018NGWF/Y018LPWF the gas inlet is located 260mm up from the base and in line with the RH leg side.
  • Page 7: Installation

    Revision 2 November 2012 WARNING! It may hazardous to use the wrong type of regulator. Storage of Appliance Always wait for the appliance to cool down before attempting to transport or store. Storage of an appliance for transport or indoors is only permissible if the cylinder is disconnected and removed from the appliance. When the appliance is not being used for a period of time it should be stored in a dry dust free environment.
  • Page 8 Revision 2 November 2012 If the burner fails to operate correctly, contact place of purchase or authorised agent for advice and service. RECOMMENDED POT SIZE Y018 Series — Minimum: Ø44cm, Maximum: Ø49cm Y028 Series — Minimum: Ø44cm, Maximum: Ø61cm CAUTION...
  • Page 9: Maintenance

    DO NOT ATTEMPT TO REPAIR IT YOURSELF. Incomplete Injector is clogged. Clean the injector. Combustion (Yellow Flame) SPECIFICATIONS Product Name 18 Jet Duckbill Burner Cooker 28 Jet Duckbill Burner Cooker Model No. Y018LPWF Y018NGWF Y028LPWF Y028NGWF Gas Type Propane Natural Propane Natural Gas Pressure 2.75kPa 0.90kPa...