Auscrown Y018LPWF-S Installation & Operating Instructions Manual

Duckbill stockpot burner with flame failure safety device

Advertisement

Quick Links

INSTALLATION & OPERATING INSTRUCTIONS
Operating instructions also on YouTube Auscrown channel
MODELS: Y018LPWF-S, Y018NGWF-S, Y028LPWF-S & Y028NGWF-S
The appliance should be installed in accordance with the requirements of AS/NZS5601.1
and the following:
Local installation codes for gas building equipment;
Manufacturer's installation instructions;
Local gas fitting regulations;
Municipal building codes; and any other relevant statutory regulation.
TO BE INSTALLED BY AN AUTHORIZED PERSON
The appliance must be:
Installed, serviced and removed by an authorised person only.
Used with a low pressure regulator.
It is the operator's responsibility to see that the burner is properly assembled and maintained.
Failure to follow instructions in this manual could result in physical injury and/or property damage.
HAZARDOUS FIRE OR EXPLOSION MAY RESULT IF INSTRUCTIONS ARE IGNORED.
FOR YOUR SAFETY
IF YOU SMELL GAS:
TURN OFF MAIN GAS SUPPLY IMMEDIATELY
EXTINGUISH ALL NAKED FLAMES AND DO NOT
OPERATE ANY ELECTRICAL APPLIANCES NEAR
THIS APPLIANCE
VENTILATE THE AREA WELL
CHECK FOR LEAKS AS DETAILED IN THIS
MANUAL
IF ODOUR PERSISTS, CONTACT PLACE OF
PURCHASE OR GAS SUPPLIER IMMEDIATELY
PLEASE READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING AND IT IS RECOMMENDED THAT THIS
AC-R2-001
DUCKBILL STOCKPOT BURNER
WITH FLAME FAILURE SAFETY DEVICE
Not to be installed for domestic use, commercial use only
FOR USE WITH NATURAL AND LP GAS ONLY
MANUAL BE RETAINED FOR FUTURE REFERENCE.
WARNING
PRECAUTIONS
Testing for gas leaks must be checked before the appliance
is used especially following disconnection and
reconnection of the cylinder
NEVER CHECK FOR LEAKS WITH A MATCH OR OPEN
FLAME
DO NOT STORE OR USE PETROLEUM PRODUCTS OR
OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE
VICINITY OF THIS APPLIANCE
AN LP CYLINDER NOT CONNECTED FOR USE IN THIS
APPLIANCE SHALL NOT BE STORED NEAR THIS
APPLIANCE
TO BE INSTALLED ON A FIREPROOF BASE ONLY
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Y018LPWF-S and is the answer not in the manual?

Questions and answers

Summary of Contents for Auscrown Y018LPWF-S

  • Page 1 WITH FLAME FAILURE SAFETY DEVICE INSTALLATION & OPERATING INSTRUCTIONS Not to be installed for domestic use, commercial use only Operating instructions also on YouTube Auscrown channel MODELS: Y018LPWF-S, Y018NGWF-S, Y028LPWF-S & Y028NGWF-S The appliance should be installed in accordance with the requirements of AS/NZS5601.1 and the following: ...
  • Page 2 IMPORTANT  Read the following instructions carefully and be sure your appliance is properly installed, assembled and cared for. Failure to follow these instructions may result in serious bodily injury and/or property damage.  This appliance is intended for commercial use only. ...
  • Page 3 PROCEDURES FOR GAS LEAKAGE The strong and distinctive odour of gas may make you aware of a gas leak. If you suspect a gas leak:  Immediately turn off the main gas supply.  Turn off all appliances and pilot lights; ...
  • Page 4 PREPARE TO ASSEMBLE THE APPLIANCE Check for damage on the appliance. If damage occurs, please contact Austcrown or your dealer. Do not use a damaged appliance. WARNING! It may hazardous to attempt to use a damaged appliance. Positioning the Appliance Only use the appliance in well ventilated areas.
  • Page 5 Within a partial enclosure that includes an overhead cover and no more than two walls. These walls may be parallel or at right angles to each other (see figures 2 & 3). Fig. 2 Fig. 3 Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply: One wall that is equivalent to at least 25% of the total wall area is completely open (see figure 4).
  • Page 6 The Gas Inlet is located for model Y028NGWF-S/Y028LPWF-S 300mm up from the base and 25mm in from the RH side leg. For model Y018NGWF-S/Y018LPWF-S the gas inlet is located 260mm up from the base and in line with the RH leg side.
  • Page 7: Installation

    WARNING! It may hazardous to use the wrong type of regulator. Storage of Appliance Always wait for the appliance to cool down before attempting to transport or store. Storage of an appliance for transport or indoors is only permissible if the cylinder is disconnected and removed from the appliance. When the appliance is not being used for a period of time it should be stored in a dry dust free environment.
  • Page 8 It is recommended that an authorised person/service agent perform all maintenance. If the burner fails to operate correctly, contact place of purchase or authorised agent for advice and service. RECOMMENDED POT SIZE Y018 Series — Minimum: Ø44cm, Maximum: Ø49cm Y028 Series — Minimum: Ø44cm, Maximum: Ø61cm CAUTION AC-R2-001 Page 8...
  • Page 9: Maintenance

    DO NOT ATTEMPT TO REPAIR IT YOURSELF. Incomplete Injector is clogged. Clean the injector. Combustion (Yellow Flame) SPECIFICATIONS Product Name 18 Jet Duckbill Burner Cooker 28 Jet Duckbill Burner Cooker Model No. Y018LPWF-S Y018NGWF-S Y028LPWF-S Y028NGWF-S Gas Type Natural Natural Gas Pressure 2.75kPa 0.90kPa 2.75kPa 0.90kPa...
  • Page 10 Austcrown Pty Ltd and their appointed agents will not be liable in respect of any misuse, which is not in accordance with the instructions and precautions specified in this booklet. AUSTCROWN PTY LTD 17 Greenaway Street, BULLEEN VIC 3105, AUSTRALIA SHOP ONLINE: www.auscrown.com.au |Follow us on www.facebook.com/auscrown Watch our product videos on www.youtube.com/auscrown...
  • Page 11 AC-R2-001 Page 11...