De-energising the system Inverter Display and Indicators LED indicators LCD panel Normal operation System operating modes Fault displays Power generation data Fault Finding Grid volt error TVS/Over power DC supply issue Inverter defect Warranty information Grant Grid Connected Inverter Warranty Notes 18/19...
1 Introduction & General Requirements 1.1 Installation Requirements 1.3 Safety instructions 1.4 Disposal information Thank you for purchasing a Grant grid- All electrical installations must be Waste Electrical connected Inverter from our Solar PV carried out in accordance with the and Electronic Range.
2 Product Information 2.1 Product Description The Grant range of PV grid-connected inverters are designed for small to medium power grid-connected PV generation systems. Features of the Grant inverter range include: * Sealed stainless steel enclosure designed and certified for IP65 protection.
Non-optimal design will lower the efficiency of the system and waste inverter power capacity. A guide matrix is provided below for each inverter model when using the Grant GPV180M Solar PV modules. CAUTION: On no account must these values be exceeded.
4 Installation WARNING: 4.1 Siting CAUTION: The inverter must not be Do not install the The Grant range of inverters can be covered or partially inverter in an explosive covered at any time, due installed either indoors or outdoors. or flammable...
4 Installation continued... 4.2 Mounting WARNING: The inverter must not be Using the two holes on the mounting installed on a flamable bracket as a guide, mark and drill two surface, due to risk of 12mm holes. fire! Assemble the expansion bolt set as shown in Figure 2, and secure the mounting plate to the wall.
10m. This includes any DC plate on the inverter matches the * For Grant AS1.0 and AS1.5 inverters, isolators that are fitted between the installation requirements for both AC heat resistant 1.5mm² flex must be array and the inverter.
4 Installation continued... 4.4 Energising the system 4.5 De-energising the system CAUTION Irrespective what condition the inverter is in, carry out the following instructions Check that the voltage of In the order they appear to safely the completed PV string isolate the inverter.
5 Inverter Display and Indicators 5.1 LED indicators As shown in Figure 5, there are 3 indicator LED’s on the front panel of the inverter. These LED’s indicate Power, Run and Fault. When the system is energised, the power LED is lit (green), otherwise it is unlit.
5 Inverter Display and Indicators continued... 5.3 Normal operation Information of normal operation is split into groups of Operating Status; Statistical Information and Operating Mode Information. The Operating status is used to display the main operating parameters of the inverter. The Statistical Information parameter shows total operating time, daily generation and total power generation .
5.4 System operating modes There are 4 operating modes as follows: 1) STAND-BY MODE The system is energised but hasn’t met the requirements to generate power (too little sunlight/small DC voltage) or the equipment has not entered generation status after restart. See Figure 14. Figure 14: Stand-by mode 2) INTERRUPTED MODE The system has shut down because of...
5 Inverter Display and Indicators continued... 5.5 Fault Displays Faults are divided into 2 categories. CAT1 and CAT2. CAT1 Fault There are 5 types of fault: 1. BIT Failure 2. Ground Failure 3. PV1 Over Voltage 4. PV2 Over Voltage Figure 18: CAT1 Display 5.
Grid Volt Error Pout: Range 0 to 3999W Figure 20: CAT2 Display Grid Volt Error Vpv1: Range 0 to 499V Figure 21: CAT2 Display Grid Volt Error Vpv2: Range 0 to 499V Figure 22: CAT2 Display Grid Volt Error E-Today: Range 0.0 to 99.9kWh Figure 23: CAT2 Display Grid Volt Error E-Total: Range 0 to 300,000 kWh...
2) Grid frequency is lower/higher Service and repair of the unit can 1) Isolate the inverter and check the than allowed only be carried out by Grant Strings for over/under voltage. Engineering or a trained Grant 3) Grid connection error (no Live...
•The Grant Solar PV System must be installed warranty. by a competent installer in accordance with the If your Grant Solar PV Grid Inverter should fail relevant Codes of Practice, Regulations and within the first ten years* of the date of Legislation in force at the time of installation.