IMPORTANT SAFETY PRECAUTIONS Prior to shipment from the factory, our products are strictly inspected for recognized product safety and electrical codes of the countries in which they are to be sold. However, in order to maintain such compliance, it is equally important to implement the following precautions when a set is being serviced.
4. Hot Chassis Warning - 7. Product Safety Notice - Some electrical and mechanical parts have special safety-related a. Some TV receiver chassis are electrically characteristics which are often not evident from connected directly to one conductor of the AC visual inspection, nor can the protection they give power cord and maybe safety-serviced without necessarily be obtained by replacing them with...
Page 6
Precautions during Servicing A. Parts identified by the ! symbol are critical for M. When installing parts or assembling the cabinet safety. parts, be sure to use the proper screws and Replace only with part number specified. tighten certainly. B. In addition to safety, other parts and assemblies are specified for conformance with regulations applying to spurious radiation.
Page 7
Safety Check after Servicing Examine the area surrounding the repaired location Chassis or Secondary Conductor for damage or deterioration. Observe that screws, parts and wires have been returned to original posi- tions. Afterwards, perform the following tests and con- Primary Circuit firm the specified values in order to verify compliance with safety standards.
STANDARD NOTES FOR SERVICING Circuit Board Indications How to Remove / Install Flat Pack-IC 1. The output pin of the 3 pin Regulator ICs is 1. Removal indicated as shown. With Hot-Air Flat Pack-IC Desoldering Machine: 1. Prepare the hot-air flat pack-IC desoldering Top View Bottom View machine, then apply hot air to the Flat Pack-IC...
Page 9
With Soldering Iron: With Iron Wire: 1. Using desoldering braid, remove the solder from 1. Using desoldering braid, remove the solder from all pins of the flat pack-IC. When you use solder all pins of the flat pack-IC. When you use solder flux which is applied to all pins of the flat pack-IC, flux which is applied to all pins of the flat pack-IC, you can remove it easily.
Page 10
2. Installation Instructions for Handling Semi- 1. Using desoldering braid, remove the solder from conductors the foil of each pin of the flat pack-IC on the CBA Electrostatic breakdown of the semi-conductors may so you can install a replacement flat pack-IC more occur due to a potential difference caused by easily.
CABINET DISASSEMBLY INSTRUCTIONS 1. Disassembly Flowchart Removal Step/ This flowchart indicates the disassembly steps for the Remove/*Unhook/ Loc. Part Fig. Unlock/Release/ cabinet parts, and the CBA in order to gain access to Note Unplug/Unclamp/ item(s) to be serviced. When reassembling, follow the Desolder steps in reverse order.
Page 12
[1] Rear Cabinet [3] Bracket [2] Stand A Shaft [4] Holder [5] Stand B Fig. D1 L4531DC...
Page 13
[12] Front Cabinet S-10 [10] [9] Function CBA Speaker S-10 S-10 S-11 Speaker Holders [11] IR Sensor S-12 [10] Speaker Speaker Holders S-11 [8] LCD Main CBA Unit & Liquid Crystal Panel Unit [6] Jack Holder [7] Main CBA Fig. D2 L4531DC...
TV Cable Wiring Diagram Function CBA CN31B To Liquid Crystal Panel Unit LCD Main CBA Unit CN106 CN311 CN312 Main CBA CN103B CN102B CN101B CN401 To Liquid CN103A CN101A CN102A Crystal Panel Unit CN403 CN802 To Speaker CN53 CN801 IR Sensor CBA To Speaker CLN53 Fig.
HOW TO INITIALIZE THE LCD TELEVISION To put the program back at the factory-default, initialize the LCD television as the following procedure. How to initialize the LCD television: 1. Turn the power on. (Use main power on the TV unit.) 2.
ELECTRICAL ADJUSTMENT INSTRUCTIONS General Note: 1. Initial Setting “CBA” is abbreviation for “Circuit Board Assem- General bly.” Enter the Service mode. NOTE: Electrical adjustments are required after replacing Set the each initial data as shown on table 1 below. circuit components and certain mechanical parts. It is Table 1: Initial Data important to perform these adjustments only after all repairs and replacements have been completed.
2. Flicker Adjustment BUTTON DATA ITEM (on the remote 1. Enter the Service mode. (See page 6-1.) VALUE control) 2. Press [2] button on the remote control unit. C-BRT(NTSC) The following screen appears. C-CNT(NTSC) C-CLR-R(NTSC) MENU → 9 C-CLR-B(NTSC) VCOM C-TNT(NTSC) C-SHR(NTSC) BRIGHT...
The following adjustment normally are not 6. [AV1(RGB)]----(APL 80%) Press “6” button to select “C-DB(C/D/S-2)” for Blue attempted in the field. Only when replacing the adjustment. Press “4” button to select “C-DR(C/D/ LCD Panel then adjust as a preparation. S-2)” for Red adjustment.When “x” value and “y” value are not within specification, adjust “C-DB(C/ 3.
SCHEMATIC DIAGRAMS / CBA'S AND TEST POINTS Standard Notes Many electrical and mechanical parts in this chassis have special characteristics. These characteristics often pass unnoticed and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts that have these special safety characteristics are identified in this manual and its supplements;...
Page 26
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON THE FOLLOWING PAGES: 1. CAUTION: FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE SAME TYPE FUSE. 2. CAUTION: Fixed Voltage (or Auto voltage selectable) power supply circuit is used in this unit. If Main Fuse (F601) is blown, first check to see that all components in the power supply circuit are not defective before you connect the AC plug to the AC power supply.
Page 28
Main 2/4 Schematic Diagram VOLTAGE CHART CN103A Pin No. Voltage L4531SCM2...
Page 29
Main 3/4 Schematic Diagram CAUTION ! NOTE: CAUTION ! For continued protection against fire hazard, The voltage for parts in hot circuit is measured using Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. replace only with the same type fuse. hot GND as a common terminal.
Page 30
Main 4/4 & IR Sensor Schematic Diagram VOLTAGE CHART CN102A Pin No. Voltage L4531SCM4...
Page 32
LCD Main 1/2 Schematic Diagram L4531SCL1...
Page 33
LCD Main 2/2 Schematic Diagram L4531SCL2...
Page 34
Main CBA Top View CAUTION ! CAUTION ! Because a hot chassis ground is present in the power supply circut, an isolation transformer must be used. For continued protection against fire hazard, Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. If Main Fuse (F601) is blown , check to see that all components in the power supply Also, in order to have the ability to increase the input replace only with the same type fuse.
Page 35
Main CBA Bottom View CAUTION ! CAUTION ! Because a hot chassis ground is present in the power Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. supply circut, an isolation transformer must be used. For continued protection against fire hazard, replace only with the same type fuse.
Page 36
Function CBA Top View IR Sensor CBA Top & Bottom View BL4520F01012-3 Function CBA Bottom View BL4520F01012-2 8-12...
WAVEFORMS WF1 ~ WF8 = Waveforms to be observed at Waveform check points. (Shown in Schematic Diagram.) Input: PAL Color Bar Signal (with 1kHz Audio Signal) Pin 14 of IC801 Pin 9 of CN103A Pin 3 of CN103A AUDIO 0.1V 0.5ms CVBS2 0.2V...
Page 38
WF9 ~ WF14 = Waveforms to be observed at Waveform check points. (Shown in Schematic Diagram.) Input: PAL Color Bar Signal (with 1kHz Audio Signal) R904 R997 WF12 10µs CTKH 20ns R907 R902 WF10 WF13 STH1 1µs STV1 R901 R905 WF11 WF14 20µs...
EXPLODED VIEWS Cabinet Function CBA SP802 CLN802 IR Sensor CBA SP801 CLN801 LCD Main CBA Unit & Liquid Crystal Panel Unit See Electrical Parts List for parts with this mark. Main CBA AC601 11-1 L4531EX...
Page 41
Packing X2-1 Packing Tape Tape Packing Tape Packing Tape Packing Tape Some Ref. Numbers are not in sequence. 11-2 L4531PEX...
MECHANICAL PARTS LIST PRODUCT SAFETY NOTE: Products marked with a PARTS produced in EU ! have special characteristics important to safety. Before replacing any of these components, read carefully the product safety notice in this service Ref. No. Description Part No. manual.
ELECTRICAL PARTS LIST PRODUCT SAFETY NOTE: Products marked with a Ref. No. Description Part No. ! have special characteristics important to safety. ELECTROLYTIC CAP . 220µF/25V M or CA1E221SP085 Before replacing any of these components, read ELECTROLYTIC CAP . 220µF/25V M CE1EMASTM221 carefully the product safety notice in this service C421...
Page 44
Ref. No. Description Part No. Ref. No. Description Part No. ACROSS THE LINE CAP . 0.1µF/250V K or CT2E104DC011 C656 ELECTROLYTIC CAP . 1µF/50V M or CE1JMASDL1R0 ACROSS THE LINE CAP . 0.1U/250V CT2E104DC015 ELECTROLYTIC CAP 1µF/50V M or CA1J1R0SP085 C608 CERAMIC CAP .
Page 45
Ref. No. Description Part No. Ref. No. Description Part No. C781 CHIP CERAMIC CAP .(1608) B K 0.01µF/50V CHD1JK30B103 ALUMINUM ELECTROLYTIC CAP 3.3µF/50V M CE1JMASTM3R3 C782 ELECTROLYTIC CAP . 47µF/16V M H7 or CE1CMAVSL470 C852 CHIP CERAMIC CAP .(1608) F Z 0.1µF/50V CHD1JZ30F104 ALUMINUM ELECTROLYTIC CAP 47µF/16V H7 CE1CMAVSM470 C853...