No indications, komplettly DARK....
1 comments:
Mr. Anderson
March 14, 2025
If your Stafford Instruments ST315 is completely dark with no indications, check the power supply to ensure the device is receiving power. If power is available but the unit remains unresponsive, possible causes could include a blown fuse, power phase failure, or internal damage. You may need to inspect the power connections, replace a faulty fuse, or seek technical support if the issue persists.
To stop the firing at any time press the START/ STOP key again Keyboard Lock Facility The keys on the ST315 can be locked so that pressing them has no effect. To review firing data press the key to enter the...
SWITCH KILN OFF! Firing ............9 Cooling ............13 To reset the ST315 turn off the power to the instrument and have the fault investigated by your installer or kiln service engineer to rectify the fault. Adjusting While Firing....... 14 Error Messages ...........
Err2 wiring open circuit. Get thermocouple °C/hr and wiring checked. Have thermocouple Next displayed is the thermocouple type to which the ST315 is set. This hr.min replaced if necessary. thermocouple type setting should match the type of thermocouple fitted to the kiln and can be R, S, K or N type.
Page 6
This will advance the segment and will immedi- ately terminate a paused soak—advancing to the next segment (if any). Changes made to the operation of the ST315 in this way are temporary An ST315 firing segment comprises a ramp followed by a soak period.
Altering a program Adjusting While Firing When the ST315 is not firing there are no lamps lit on the mimic panel, the run lamp is off and the display shows the kiln temperature with the °C Firing values can be adjusted while the ST315 is firing. Also there are indicator lit.
Page 8
When the kiln has cooled to less than 40°C the display alternates every 5 seconds between the kiln temperature and End To return the ST315 back to idle condition ready for the next firing press the START/STOP key (or turn off the power to the instrument).
Page 9
To start a firing press the START/STOP key. The RUN lamp will light. If the ST315 is programmed to heat the kiln at a faster rate than the kiln is To stop the firing prematurely press the START/STOP key again.
Page 10
Program Record Sheet Program No. Segment Ramp Soak Temp Soak Time Notes °C/hr °C hr.min Page ST315 User Handbook ST315 User Handbook Page 11...
Need help?
Do you have a question about the ST315 and is the answer not in the manual?
Questions and answers
No indications, komplettly DARK....
If your Stafford Instruments ST315 is completely dark with no indications, check the power supply to ensure the device is receiving power. If power is available but the unit remains unresponsive, possible causes could include a blown fuse, power phase failure, or internal damage. You may need to inspect the power connections, replace a faulty fuse, or seek technical support if the issue persists.
This answer is automatically generated