IMPORTANT SAFETY INSTRUCTIONS
WARNING Shock and Energy Hazards
Be sure to read the safety guidelines and pay attention to
all cautions and warnings throughout the installation
procedure.
The installer is responsible for ensuring compliance with
the installation codes for your particular application.
Disconnect all sources of AC and DC power before
proceeding
Especifications
Model
Output current
Charging type
Bulk stage
Absortion stage
Float stage
AC input voltage
Frequency
Charger efficiency
Recommended battery type and size
Over load protection
Over temperature protection
Output reverse protection
Operating temperature
Storage temperature
Battery connection
Dimension (L x W x H) mm
Net weight (Kg)
AC input cable
Precauciones de seguridad
1. Do not expose the charger to rain, snow, spray, or bilge water. To reduce risk of fire hazard, do not cover or obstruct the
ventilation openings. Do not install the charger in a zero-clearance compartment. Overheating may result.
2. The charger is designed to be permanently connected to your AC and DC electrical systems.
3. Before using the charger, read all instructions and cautionary markings on the charger, the batteries, and all appropriate sections
of this guide.
4. Use only attachments recommended or sold by the manufacturer. Doing otherwise may result in a risk of fire, electric shock, or
injury to persons.
5. Do not disassemble the charger. Attempting to service the unit yourself may result in a risk of electrical shock or fire. Internal
capacitors remain charged after all power is disconnected.
6. The charger must be provided with an equipment-grounding conductor connected to the AC input ground.
7. To reduce the risk of electrical shock, disconnect both AC and DC power from the charger before attempting any maintenance
or cleaning or working on any circuits connected to the charger. Turning off controls will not reduce this risk.
8. Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged in any.
9. To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and that wire is not undersized. Do
not operate the charger with damaged or substandard wiring.
User´s manual
FUM – 1240CBP // FUM – 2420CBP
3 stage battery charger
User's manual
FUM-1240CBP
40A
14.5V (±0.5V), 40A
14.5V (±0.5V), 40A~4A
13.6V @ min. 0.5A (depends on battery
status)
ON/OFF SWITCH
Charging Status
3 stage
27.2V @ min. 0.25A (depends on battery
115V (90~135V) // 230V (180~270V)
50 / 60Hz
85%
Lead-acid batteries, 250Ah and up
Yes
Yes
Yes
Fuse blow
0ºC ~ 30ºC
-25ºC ~ 70ºC
1 positive terminal, 1 negative terminal
380 x 179 x 82
4.5
Yes
- 1 -
AC Input
Remote Control
FUM-2420CBP
20A
29.0V (±1.0V), 20A
29.0V (±1.0V), 20A~2A
status)
FUM - 1240CBP // FUM - 2420CBP
Need help?
Do you have a question about the FUM – 1240CBP and is the answer not in the manual?
Questions and answers