Cadac M16 Installation & User Manual page 41

Remote controlled microphone amplifier
Table of Contents

Advertisement

Revision MA2005-7
M16: wiring for USB connector
Pin 1:
N/C
Pin 2:
DATA +
Pin 3:
DATA –
Pin 4:
COMMON
Shell:
COMMON
Important notes:
All CADAC products are Common Bonded. This is part of the
design procedure to ensure compliance with the European
EMCD (Electro Magnetic Compliance Directive): BSEN55103-1
(Emissions) and BSEN55103-2 (Immunity).
Common Bonding means a single conductive structure for all
reference, signal and power return currents.
COMMON = Safety Earth, GROUND, 0V, GND bonded together.
All 'D sub' connectors used for external connections should
be purchased with a conductive shell and the cable shield
MUST be bonded to the shell.