Advertisement

Quick Links

User's Guide
Carefully read and fully understand
instructions before using this unit.
2002.04
16004104060

Advertisement

Table of Contents
loading

Summary of Contents for Tando TR-71S

  • Page 1 User’s Guide Carefully read and fully understand instructions before using this unit. 2002.04 16004104060...
  • Page 2: Notices About This User's Guide

    Safety Precautions and Instructions ■ Notices about this User’s Guide In an attempt to ensure safe operation of our products and to protect them Carefully read and fully understand these instructions before using this unit. ● from the possibility of damage throughout this User’s Guide the following All rights of this User’s Guide belong to T&D Corporation.
  • Page 3 DANGER CAUTION Do not take apart, repair or modify the main unit. The Thermo Recorder is a device to measure temperature. It may cause fire, electrocution or damage. Please ask the shop Do not use this unit for any purpose other than temperature where you bought the product or T&D to carry out any repairs.
  • Page 4 CAUTION CAUTION ■ TR-0106, Standard Temperature Sensor of TR-71S Remove batteries from any unit that is not to be used for a long period of time. Use the sensor only within the measurable temperature Batteries left in a unit not being used for a long time may leak range (-40 to 110℃...
  • Page 5: Table Of Contents

    Outline of the Product ■ Outline Introduction Thermo Recorder TR-71S is a 2-channel data logger unit designed to Notices about this User’s Guide ........ 1 measure, display and record temperature. The TR-72S is a data logger Safety Precautions and Instructions ......2 designed to measure, display and record temperature on 1 channel and Table of Contents............
  • Page 6: Part Names And Functions

    Ch. 1 and 2 are connected External Sensor External Sensor (Channel 1) Sensor Connection Jack Power Switch ■ TR-72S (Channel 2) Available only for TR-71S Standard Temperature/Humidity Sensor (TR-3110) ■ Right Side View Connection condition Channel 1 Channel 2 Communication Cable Temp/Humidity sensor connected External (Temp.)
  • Page 7: Temperature And Humidity Sensors (Tr-72S)

    Temperature and Humidity Sensors Install Batteries and Turn Power On ■ Battery Installation Caution ● The replacement period for the standard sensor is 1 year. Replace it Open the battery cover on the backside of the main unit. 。 when 1 year has passed after opening the bag. When using the Install 2 AAA-size alkaline batteries in the correct direction to align Temperature and Humidity Sensor, the surface can become dirty and +...
  • Page 8: Battery Life

    Battery Life Approximate time till [BAT] mark appears on the LCD display after Continuing to use the unit with the [BAT] mark displayed and without installing a new set of batteries is as follows: changing the batteries will cause the display to change to [SLP] and the unit will enter sleep.
  • Page 9: Lcd Display

    Press the [REC/STOP] Button for more than 3 seconds or until "REC" more. appears on the LCD and recording starts. Figures in ( ) show the usage of TR-71S wide range ※ temperature sensor. If the unit is set for Endless Method "LOOP" will be displayed on ※...
  • Page 10: Start Recording And Set Recording Conditions Via Computer

    Start Recording and Set Recording Conditions via Computer ■ Set Recording Interval Start Recording and Recording Conditions can be set via your computer by CAUTION using the software "Thermo Recorder for Windows". The following settings can also will be made: The Recording Interval cannot be set or changed during recording and /or during wait for a programmed start.
  • Page 11: Display Amount Of Recorded Data

    Endless Loop connection. Method ● Connecting to a wrong port will result in communication failure. ● In One Time Method, the display will read [FULL] when it reaches TR-71S Computer TR-72S capacity and recording will stop. Connect Connect ● In Endless Loop Method, when it reaches capacity the indication will remain the same but recording will continue.
  • Page 12: Collecting Recorded Data

    With our exclusive software "Thermo Recorder for Windows" it is possible to ■ Temperature Sensors (for TR-7 Series) download all of the recorded data from TR-71S and TR-72S as well as carry Possible Measurement Range: -40 to 110℃ out the following functions in managing the data.
  • Page 13 ※ Only stainless section is water resistant. Humidity Measurement Accuracy: ± 5%RH (at 25℃ and 50%RH) Service Life: 1 year under normal conditions ■ Wide Range Temperature Sensors (for TR-71S) Operational Conditions: No Dew Condensation or Water Leakage No contact with organic solvents, solution or CAUTION gasses emitted from spoiled foods.
  • Page 14: Product Specifications

    ※ 1 There are 2 types of temperature sensors covering different ranges for use with the TR-71S. For details, see page 22 "Optional Sensors List". dealer. ※ 2 Battery life differs depending on measurement environment and battery performance.
  • Page 15 5652-169 Sasaga Matsumoto City NAGANO 399-0033 JAPAN Phone:+81-263-27-2131 Facsimile:+81-263-26-4281 Homepage:http://www.tandd.co.jp/english/ E-Mail:overseas@tandd.co.jp...