Summary of Contents for Tando TR-71U

  • Page 1 User’s Manual Thank you for purchasing our product. Carefully read this instruction manual before using this unit. Copyright 2004 T&D Corporation. All rights reserved. 2004.08 16004374040...
  • Page 2 Notices about this User’s Manual FCC Compliance Statement for American Users This device complies with Part 15 of the FCC Rules. In order to properly use this product, please carefully read this manual before Operation is subject to following two conditions: (1) this device may not using.T&D Corporation accepts no responsibility for any malfunction of and/or cause harmful interference.
  • Page 3: Safety Precautions And Instructions

    Safety Precautions and Instructions DANGERS To ensure safety be sure to obey all of the following Do not take apart, repair or modify the main unit. warnings. Doing so may cause fire or electrocution. The following items should be strictly obeyed for the safe usage of this unit, and for protecting yourself and other people from bodily harm and/or damage If water or a foreign body enters into this unit, to property.
  • Page 4 CAUTIONS CAUTIONS Do not use any other batteries than those that are Do not use batteries other than specified. Doing so may cause fire or damage. specified in this User's Manual. It may cause a fire or other trouble including malfunction.
  • Page 5 Cautions about using the Sensors Cautions about using the Sensors Cautions about using the temperature sensor TR-0106 [Handling the temperature/humidity sensor] The temperature/humidity sensor should probably be changed after a The possible temperature measurement range for period of about one year. After removing the sensor from its package, this sensor is -40 to 110℃...
  • Page 6: Table Of Contents

    Turning on the Power ------------------------------------------------------------ 8 Temperature Measuring Range : -60 to 155℃ (TR-71U) The TR-71U with the sensor included in this package can measure and Installing the USB Device Driver ---------------------------------------------- 9 record in a range of -40 to 110℃ , but by purchasing one of our optional...
  • Page 7: Package Contents

    Endless Mode : When the number of recorded readings reaches 8000, the oldest data reading will be overwritten and recording will continue. Thermo Recorder TR-71U × 1 unit T&D Recorder for Windows Backup Function Software CD-ROM × 1 When battery power becomes low, a battery life warning signal will appear in the unit’s LCD display and if the battery power becomes even lower the...
  • Page 8: Part Names And Functions

    Part Names and Functions 【TR-72U】 Part Names [FRONT] Thermo Recorder TR-72U × 1 unit T&D Recorder for Windows Software CD-ROM × 1 DISPLAY INTERVAL REC/STOP button button button AA Alkaline Battery USB Communication Cable Temperature Sensor (LR6) × 1 US-15C × 1 TR-3100 ×...
  • Page 9: Installing The Battery

    Installing the Battery LCD Display 1.Remove the battery cover form the back of the unit. ② ③ ④ ⑤ ⑥ 2.Insert 1 AA alkaline battery, making sure that the + and – are in the correct direction. - Always use a new battery. ⑦...
  • Page 10: Turning On The Power

    1.By holding in the POWER switch at the left side, the unit will turn on. and Windows. It is necessary for communication via USB between your computer and any TR-71U/72U device. After installing, your computer will be able to detect and recognize TR-71U/72U devices that have been connected with a USB cable.
  • Page 11 4.By connecting a data logger to the USB cable already connected to your computer, the [Add Hardware Wizard] will automatically open. 5.By checking [Install the Software automatically (Recommended)] and clicking [Next], the software will automatically be installed.
  • Page 12: Windows 2000

    For Windows 2000: 1.Turn on your computer and open Windows. 2.After Windows has been completely started up, connect the supplied USB cable to a USB port on your computer. 3.Insert the attached CD-ROM in the CR-ROM drive. ※ If the Installation Window opens, close it. 4.By connecting a data logger to the USB cable already connected to your computer, the [Found New Hardware Wizard] will automatically open.
  • Page 13 8.By clicking the [Next] button, installation will begin.
  • Page 14: Windows Me

    For Windows Me: 1.Turn on your computer and open Windows. 2.After Windows has been completely started up, connect the supplied USB cable to a USB port on your computer. 3.Insert the attached CD-ROM in the CR-ROM drive. ※ If the Installation Window opens, close it. 4.By connecting a data logger to the USB cable already connected to your computer, the [Add New Hardware Wizard] will automatically open.
  • Page 15: Windows 98

    Checking After Connecting For Windows 98: 1.Open the [Control Panel] and double click on [System]; the system 1.Turn on your computer and open Windows. properties will be displayed. 2.After Windows has been completely started up, connect the supplied 2.Click the [Device Manager] Tab, and the [Device Manager] Window will USB cable to a USB port on your computer.
  • Page 16 6.Check [Search for the best driver your device (Recommended)] and click the [Next] button. Check...
  • Page 17 Checking After Connecting Connecting the Sensor. 1.Open the [Control Panel] and double click on [System]; the system properties will be displayed. [TR-71U] 2.Click the [Device Manager] Tab, and the [Device Manager] Window will appear. 「Device Manager」Tab If a temperature sensor is connected to only the ch. 2 jack, the internal sensor will be used to measure for ch.
  • Page 18: Starting Recording From Main Unit Switch

    Starting Recording from Main Unit Switch [Handling the temperature/humidity sensor] By pressing the REC switch on the main unit you can start a recording The temperature/humidity sensor should be changed after a period of about session immediately. one year. After removing the sensor from its package, please change the temperature/humidity sensor after one year’s usage.
  • Page 19: Setting Recording Interval From Main Unit Switch

    You can make or change recording interval settings from the "INTERVAL" a failure to install properly, the following display will appear in the Device switch on the front of the TR-71U/72U main unit. Manager. 1.Press in the [INTERVAL] button on the front of the device until the recording interval appears in the display.
  • Page 20: Specifications

    Software set × 1 / User's Manual (Warranty) × 1 *1: There are two types of temperature sensor for TR-71U depending on measurement range. For details see Optional Accessories on p.29. *2: Battery life depends upon the measuring environment, recording interval, and quality...
  • Page 21 TR-0206 Stainless Protection Sensor Sensor Extension Cable (Temp Sensor Only) Cable Length : 0.6m unit : millimeters Thermal-Constant Time : TR-1C30 In the air : Approx. 75 Sec. Cable length : 3.0m TR-0306 Stainless Protection Sensor Cable Length : 0.6m Materials: ①...
  • Page 22 Serial Communication Cable (for TR-71U/72U) TR-07C Serial Communication Cable Cable Length:about 1.0 m Connector Type:Specialized Connector D-sub9pin For communication with computer TR-4C10 Serial Communication Cable Cable Length:about 1.0 m Connector Type:Specialized Connector D-sub9pin For communication with RTR-57C Wall Attachment(for TR-71U/72U)...
  • Page 23 Please stop by and see what we have to offer. h ttp ://ww w.t andd.j p/ Thermo Recorder TR-71U/TR-72U User's Manual Published by T&D CORPORATION Copyright 2004 T&D Corporation. All rights reserved.