Model Nomenclature - Geostar Aston Compact Series Installation Manual

Water source/geothermal heat pump
Table of Contents

Advertisement

ASTON COMPACT INSTALLATION MANUAL

Model Nomenclature

1-2
3
GB
V
Model Type
Model Type
GB = Aston Compact
GB = Aston Compact
Cabinet Configuration
Cabinet Configuration
V = Vertical
V = Vertical
H = Horizontal
H = Horizontal
Unit Capacity
Unit Capacity
Single Speed
Single Speed
009, 012, 015, 018, 024, 030,
009, 012, 015, 018, 024, 030,
036, 042, 048, 060, 070
036, 042, 048, 060, 070
Dual Capacity
Dual Capacity
026, 038, 049, 064, 072
026, 038, 049, 064, 072
Discharge Configuration
Discharge Configuration
T = Top (vertical)
T = Top (vertical)
E = End (horizontal)
E = End (horizontal)
S = Side (horizontal)
S = Side (horizontal)
Return Air Configuration
Return Air Configuration
L = Left
L = Left
R = Right
R = Right
Voltage
Voltage
0 = 208-230/60/1
0 = 208-230/60/1
2 = 265-277/60/1 (009-038)
2 = 265-277/60/1 (009-038)
3 = 208-230/60/3 (024-072)
3 = 208-230/60/3 (024-072)
4 = 460/60/3 (024-072)
4 = 460/60/3 (024-072)
5 = 575/60/3 (PSC only 042, 048, 060, 070)
5 = 575/60/3 (PSC only 042, 048, 060, 070)
Refrigeration Option
Refrigeration Option
0 = None
0 = None
2 = HWG only w/o pump (Vertical 018-070)
2 = HWG only w/o pump (Vertical 018-070)
G = Hot Gas Bypass (015-072)
G = Hot Gas Bypass (015-072)
R = Hot Gas Reheat (015-072)
R = Hot Gas Reheat (015-072)
B = Hot Gass Bypass w/ Hot Gas Reheat (015-072)
B = Hot Gass Bypass w/ Hot Gas Reheat (015-072)
Blower Option
Blower Option
0 = PSC Blower (single speed)
0 = PSC Blower (single speed)
1 = Variable Speed ECM Blower (015-072)
1 = Variable Speed ECM Blower (015-072)
2 = High Static Variable Speed ECM Blower
2 = High Static Variable Speed ECM Blower
(036, 038, 042, 048, 049)
(036, 038, 042, 048, 049)
3 = High Static PSC Blower (024, 030, 036, 042, 048)
3 = High Static PSC Blower (024, 030, 036, 042, 048)
4 = 5-Speed ECM Blower (015-072)
4 = 5-Speed ECM Blower (015-072)
Water Coil Option
Water Coil Option
C = Copper
C = Copper
D = Insulated Copper
D = Insulated Copper
N = Cupronickel
N = Cupronickel
P = Insulated Cupronickel
P = Insulated Cupronickel
NOTES: Phase guard only available on 208-230/60/3, 460/60/3, and 575/60/3
NOTES: Phase guard only available on 208-230/60/3, 460/60/3, and 575/60/3
4-6
7
8
9
10
11
12
13
036
T
L
0
0
0
C
A
14
15
16
17
18
19
20
21-22
N
A
N
1
A
1
0
SS
4
23
*
Vintage
Vintage
* = Factory Use Only
* = Factory Use Only
Non-Standard Option Details
Non-Standard Option Details
SS = Standard Option
SS = Standard Option
Drain Pan Option
Drain Pan Option
0 = Composite, No Secondary Connection
0 = Composite, No Secondary Connection
1 = Composite, Secondary Connection
1 = Composite, Secondary Connection
2 = Stainless Steel, No Secondary Connection
2 = Stainless Steel, No Secondary Connection
3 = Stainless Steel, Secondary Connection
3 = Stainless Steel, Secondary Connection
Air Coil Option
Air Coil Option
1 = Standard
1 = Standard
2 = FormiShield™
2 = FormiShield™
Filter Option
Filter Option
A = MERV 4
A = MERV 4
B = MERV 13
B = MERV 13
Cabinet Option
Cabinet Option
0 = Unpainted Cabinet, Filter Rail
0 = Unpainted Cabinet, Filter Rail
1 = Painted Cabinet, Filter Rail
1 = Painted Cabinet, Filter Rail
2 = Unpainted Cabinet, 4-sided Filter Rack
2 = Unpainted Cabinet, 4-sided Filter Rack
3 = Painted Cabinet, 4-sided Filter Rack
3 = Painted Cabinet, 4-sided Filter Rack
Electrical Option
Electrical Option
N = None
N = None
®
®
A = GeoStart
A = GeoStart
Only
Only
E = GeoStart and Disconnect
E = GeoStart and Disconnect
P = Phase Guard, No Disconnect
P = Phase Guard, No Disconnect
B = Phase Guard, Disconnect
B = Phase Guard, Disconnect
D = No Phase Guard, Disconnect
D = No Phase Guard, Disconnect
Controls Option
Controls Option
TM
TM
A = Aurora
A = Aurora
Base Control (ABC)
Base Control (ABC)
4 = FX10 std. no communication
4 = FX10 std. no communication
5 = FX10 w/ Open N2 Com Card
5 = FX10 w/ Open N2 Com Card
6 = FX10 w/ LonWorks Com Card
6 = FX10 w/ LonWorks Com Card
7 = FX10 w/ BacNet Com Card
7 = FX10 w/ BacNet Com Card
Water Control Option
Water Control Option
N = None
N = None
R = Water Flow Regulator
R = Water Flow Regulator
V = 2-Way Valve
V = 2-Way Valve
B = 2-Way Valve w/ Water Flow Regulator
B = 2-Way Valve w/ Water Flow Regulator
Sound Kit Option
Sound Kit Option
A = None
A = None
B = Sound Kit
B = Sound Kit
Rev.: 25 February 2013D
Rev.: 25 February 2013D

Advertisement

Table of Contents
loading