Geostar Sycamore Series Manual

Geostar Sycamore Series Manual

Variable speed geothermal heat pumps 3 to 5 tons
Hide thumbs Also See for Sycamore Series:

Advertisement

Quick Links

Sycamore Series
VARIABLE SPEED GEOTHERMAL HEAT PUMPS
3 TO 5 TONS
Submittal Data
English Language
IP/Metric Units
SD2700AGA 02/21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sycamore Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Geostar Sycamore Series

  • Page 1 Sycamore Series VARIABLE SPEED GEOTHERMAL HEAT PUMPS 3 TO 5 TONS Submittal Data English Language IP/Metric Units SD2700AGA 02/21...
  • Page 2 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Model Nomenclature Model 14 - Sycamore Variable Speed Future Option 0 - Standard Type 1 - Vertical Controls Option 2 - Horizontal J - Aurora Variable Speed Controls...
  • Page 3 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: AHRI/ISO 13256-1 Performance Ratings Variable Speed ECM Motor AHRI/ASHRAE/ISO 13256-1 English (IP) Units Water Loop Heat Pump Ground Water Heat Pump Ground Loop Heat Pump Flow Rate...
  • Page 4: Vertical Dimensional Data

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Vertical Dimensional Data Top Air Discharge LEFT RETURN RIGHT RETURN 1.9in [4.8cm] 1.9in [4.8cm] I K J D E H F FRONT 2 ft [61 cm]...
  • Page 5 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Vertical Dimensional Data cont. Bottom Air Discharge RIGHT RETURN LEFT RETURN 1.70 (4.3 cm) LEFT SIDE RIGHT SIDE 1.90 (4.7 cm) FRONT 2 ft [61 cm]...
  • Page 6 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Vertical Dimensional Data cont. Rear Air Discharge 1.90 in. [4.8 cm] 1.90 in. [4.8 cm] FRONT 2 ft [61 cm] 2 ft [61 c Primary Service Access...
  • Page 7: Horizontal Dimensional Data

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Horizontal Dimensional Data TOP VIEW 2.1in [5.4cm] MOUNT (2) HANGER BRACKETS AS SHOWN TO ALLOW ACCESS TO FILTER 2 ft [61 cm] 2 ft [61 cm]...
  • Page 8: Physical Data

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Physical Data Model Compressor (1 each) Variable Speed Scroll Factory Charge R410a, oz [kg] Vertical 90 [2.55] 120 [3.40] 140 [3.96] (Aluminum tube and fin air coil)
  • Page 9: Auxiliary Heat Ratings

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Auxiliary Heat Ratings Btu/h Model Compatibility Model Stages Min CFM 208V 230V 208V 230V EAL(H)10A 24,600 32,700 1100 • • • EAL(H)15A 10.8 14.4 36,900 49,100 1250 •...
  • Page 10: Blower Performance Data

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Blower Performance Data Variable Speed ECM Blower Motor Air Flow Model Speed Speed Speed Speed Speed Speed Speed Speed Speed Speed Speed Speed 1100 1220 1330...
  • Page 11: Operating Limits

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Operating Limits Cooling Heating Operating Limits (°F) (°C) (°F) (°C) Air Limits Min. Ambient Air Rated Ambient Air 26.7 21.1 Max. Ambient Air 37.8 29.4 Min. Entering Air 10.0...
  • Page 12: Correction Factor Tables

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Correction Factor Tables Air Flow Corrections (Compressor Speeds 1-3) Airflow Cooling Heating CFM Per Ton % of Nominal Total Cap Sens Cap Power Heat of Rej...
  • Page 13: Antifreeze Corrections

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Antifreeze Corrections Catalog performance can be corrected for antifreeze use. Please use the following table and note the example given. Antifreeze Type Antifreeze % by wt...
  • Page 14: Performance Data

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Performance Data 036 - 50% Part Load HEATING - EAT 70°F COOLING - EAT 80/67 °F Flow Flow Airflow Power Airflow Power °F °F PSI FT...
  • Page 15 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Performance Data cont. 036 - 100% Full Load HEATING - EAT 70°F COOLING - EAT 80/67 °F Flow Flow Airflow Power Airflow Power °F °F PSI FT...
  • Page 16 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Performance Data cont. 048 - 50% Part Load HEATING - EAT 70°F COOLING - EAT 80/67 °F Flow Flow Airflow Power Airflow Power °F °F PSI FT...
  • Page 17 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Performance Data cont. 048 - 100% Full Load HEATING - EAT 70°F COOLING - EAT 80/67 °F Flow Flow Airflow Power Airflow SC MB- Power °F °F...
  • Page 18 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Performance Data cont. 060 - 50% Part Load HEATING - EAT 70°F COOLING - EAT 80/67 °F Flow Flow Airflow Power Airflow Power °F °F PSI FT...
  • Page 19 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Performance Data cont. 060 - 100% Full Load HEATING - EAT 70°F COOLING - EAT 80/67 °F Flow Flow Airflow Power Airflow Power °F °F PSI FT...
  • Page 20: Wiring Schematics

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Wiring Schematics Aurora Variable Speed Orange(9) Ext Pump Ext Pump Pump Pump Pump 1/2 hp Total 1/2 hp Total 208-230/60/1 G G G Brown(10) Violet(8) Violet(7)
  • Page 21 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Wiring Schematics cont. Aurora Variable Speed cont. With optional EA Series 20kW Auxiliary Electric Heat Shown 60 AMP 60 AMP Legend Legend BRK2 BRK1 Factory Low voltage wiring...
  • Page 22 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Wiring Schematics cont. Aurora Variable Speed Drive/EEV Wiring Suction Pressure Discharge Pressure Enteri n g (Red Pl u g) (Green Plug) Compressor Discharge Water Temp Unit Power...
  • Page 23 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Wiring Schematics cont. Aurora Variable Speed Drive/EEV Wiring cont. Suction Discharge Bipolar Stepper Motor Line Temp Air Temp Legend Legend Yellow Orange Factory Low vol t age wi r ing...
  • Page 24: Engineering Guide Specifi Cations

    The drain pan shall be of plastic construction to inhibit corrosion and bacterial growth. Drain outlet shall be located on pan as Furnish and install GeoStar Water Source Heat Pumps, as to allow complete and unobstructed drainage of condensate. indicated on the plans. Equipment shall be completely assembled, The unit as standard will be supplied with solid-state electronic piped and internally wired.
  • Page 25: Hanger Kit

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Engineering Guide Specifi cations cont. Electrical Piping A control box shall be located within the unit compressor Supply and return water connections shall be 1 in. [25.4 mm] FPT...
  • Page 26 Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Engineering Guide Specifi cations cont. Electronic Air Cleaner (field-installed) A 1 in. [25 mm] electronic air cleaner, cleanable 97% efficiency at 0.3 microns and larger, shall be provided in lieu of the standard throwaway filter.
  • Page 27: Revision Guide

    Sycamore Series Contractor: P.O.: 3 - 5 Tons 60Hz Engineer: Project Name: Unit Tag: Revision Guide Pages: Description: Date: Misc Updated with Aluminum Air Coils 04 Dec 2020 Misc Updated Schematics, General Installation Information, Unit Startup (UPMXL) 20 Sept 2020 Misc.

This manual is also suitable for:

036048060

Table of Contents