Loading Absolute Focap Tape With The Loader/Verifier - Singer SKC-2000 User Manual

Computer control unit
Table of Contents

Advertisement

_Y_2_4_0_A.,....2 ... 00_M_2_0_2_
REV.
-=-
THE SINGER COMPANY
KEARFOTT DIVISION
1.
Set the computer to STOP.
2.
Set the HALT switch to ON.
3.
Set the DISPLAY switch to A (accumulator)
4.
The INSTRUCTION switches to a JGU 78CO (643078CO)
5.
Reset the program counter by depressing the MASTER RESET pushbutton.
6.
Set the PANEL MODE switches to PANEL.
7.
Toggle the RUN/STOP switch and make sure that the JGU instruction is read in, by
checking that the corresponding bits illuminate on the I NSTRUCTION display, and verify
that the ADDRESS bits illuminate to 78CO.
8.
Set the MEMORY WRITE switches to ON (if loading into protected memory).
9.
Set the two PANEL MODE switches to MEM.
10. Set the computer to RUN. The tape unit is now activated. The High Speed Reader will
run until it reaches the stop code at the end of the tape and will then halt. The teletype
reader must be set to START and it will continue to run and must be set to STOP when
the computer halts. After loading is complete, continue at 3.5.1.
3.7 LOADING ABSOLUTE FOCAP TAPE WITH THE LOADER/VERIFIER
The procedure for loading FOCAP format tape is similar to the steps outlined in paragraph 3.6
except for the starting address. The appropriate START address is obtained in the Loader/Verifier
program listing. To verify that the assembled program has been entered into memory correctly, the
tape is rewound and re-run after setting the appropriate PROGRAM SWITCHES. The tape to be
loaded must be positioned with the RUBOUTS/DELETES (all holes), that precede the load data,
positioned under the read head.
The function of the PROG RAM SWITCHES for loading and verifying either odd or even parity
tapes is as follows.
3-12
F42021
2/72