Wiring Diagram - BENSON RS UHA Assembly And Use Manual

Gas fired room sealed unit heaters
Table of Contents

Advertisement

WIRING DIAGRAM SINGLE AND TWO STAGE
Type 1-2-3-4-5
SND
LF
LL
LB
RST
SE
KEY
SND
Temperature probe
TR
Regulatory control thermostat (auto reset)
LM
LIMIT thermostat (Manual reset)
EVG1-I° Gas solenoid valve 1
EVG1-II° Second stage gas valve 1 (Two Stage
version only)
C
Fan capacitor
FAN 1
Axial fan 1
FAN 2
Axial fan 2 (type 5)
F1-F2
Line fuses
LF
Green working light
LL
High temperature indication light
LB
Lockout indication
RST
Lockout reset
EF
Flue venter
TR
LM
J9
J12
EF
C
FAN 1
N
F1
F2
NA
NC
COM
COM
PA
PA
Differential pressure switch
IGN1
Ignition transformer
EA1
Spark electrode
ION
Ionisation probe
SE
Electrical control board
IMT (*)
Fused isolator
MS (*)
Fire damper connection (accessory)
RSTR (*) Remote reset connection
TA (*)
Room thermostat connection
VM (*)
Fan switch connection
SF (*)
Second stage gas valve connection
(*) External to the heater customer supply
10
C
FAN 2
II°
SF
IMT
MS
RSTR
TA
VM
IGN1
EA1
ION

Hide quick links: