4.2 Power Supply Requirements

A/C Line voltage range
A/C Line frequency range
Input Voltage transients
Current
Peak surge current
Leakage current
Power line surge
100 V ~ 240 V
50 ± 3Hz, 60 ± 3Hz
90-264 voltage AC for 10 sec @40℃
1.5A max at 100V; 0.8A max at 240 V
< 60A peak at 240 VAC and cold starting
< 30A peak at 120VAC and cold starting
< 3.5mA
No advance effects (no loss of information or defect)
with a maximum of 1 half-wave missing per second