DESCRIPTION OF MAIN CIRCUIT OPERATION

MODEL RAI-50NH5
1. Reset Circuit
Voltage supply to
pin
Voltage at pin
of microcomputer
The reset circuit initializes the microcomputer program when power is ON or OFF.
G
Low voltage at pin
G
When power "ON" 5V voltage rises and reaches 4.4V, pin 1 of IC521 is set to "Hi". At this time the
G
microcomputer starts operation.
When power "OFF" voltage drops and reaches 4.2V, pin 1 of IC521 is set to "Low". This will RESET the
G
microcomputer.
0274E Pg 57-88(RAI-50NH5)
5V
2
1
5
3
IC521
Voltage
5.0V
2
of IC521
Reset release at 4.4V
voltage
5.0V
7
resets the microcomputer and Hi activates the microcomputer.
7
59
R522
0V
Fig. 1-1
Reset enter at 4.2V
Fig. 1-2
– 59 –
19/10/05, 3:34 PM
NORMAL : HI
RESET
: LO
7
RES
Microcomputer