Pre-Start Check List; Lighting Instructions - Charmglow Stainless Steel Natural Gas Drop-In Sear Burner Owner's Manual

Outdoor gas sear burner
Table of Contents

Advertisement

PRE-START CHECK LIST:

Property damage, bodily harm, severe burns, and death could result from failure to follow these
safety steps. These steps should be performed after the sear burner has been assembled, stored,
moved, cleaned, or repaired. DO NOT operate this sear burner until you have read and understand
ALL of the warnings and instructions in this manual.
PRE-START CHECK LIST:
Ensure that the sear burner is properly assembled.
Inspect the gas supply hose for burns, chaffing, kinks, and proper routing before each use. If it is evident
there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the sear burner being
used. A replacement hose can be obtained by contacting customer service at 800-527-0717.
Leak check all gas connections and hose. See section on "Leak Testing".
Ensure that all electrical supply cords are properly grounded. Keep any electrical supply cord and the
fuel supply hose away from any heated surfaces. Hose should be at least 3 inches from hot surfaces.
Position your grill on level ground in a well ventilated location, a safe distance from combustible
materials, buildings and overhangs.
Properly place the empty grease tray under the grease drain hole in the bottom of the sear burner to
catch grease during use.
DO NOT obstruct the flow of combustion and ventilation air.
Read, understand and follow all warnings and instructions contained in this manual. DO NOT skip
any of the warnings and instructions contained in the preceding sections of this manual.

LIGHTING INSTRUCTIONS:

Follow the instructions exactly.
1. OPEN THE SEAR BURNER LID before attempting to light a burner so that fumes do not
accumulate inside the sear burner. An explosion could occur if sear burner lid is down.
2. Check that all burner control knobs and the natural gas supply are turned to the "OFF" position.
3. Turn on natural gas supply.
4. DO NOT stand with head, body, or arms over the sear burner when lighting.
LIGHTING THE SEAR BURNER:
1. Open lid before lighting sear burner.
2. Make sure control knob is in the "OFF" position.
3. Push and turn sear burner control knob to the "HIGH" position.
4. Press the electronic igniter on the sear burner and hold for
3 – 5 seconds to light burner.
5. If ignition does NOT occur in 5 seconds, turn control knob to
"OFF", wait 5 minutes to allow gas to dissipate and repeat lighting procedure.
6. To turn off, turn control knob clockwise until it locks in the "OFF" position.
Note: If burner does not light or flame is too low, you may have spider or other insect blockage in burner.
WARNING
WARNING
WARNING
SEAR BURNER
6