Specifications; Duty Cycle - Boss ARC 140 Operating Manual

Table of Contents

Advertisement

2.02

Specifications

MODEL
Input voltage and frequency and phases
KVA @ max output
Max current
Output current range
Open circuit voltage
Duty cycle at 40¡æ
Weight
Dimensions (mm)
2.03

Duty cycle

The duty cycle of a welding power source is the percentage of a ten (10) minute period that it can be
operated at a given output without causing overheating and damage to the unit. If the welding amperes
decrease, the duty cycle increases. If the welding amperes are increased beyond the rated output, the duty
cycle will decrease.
WARNING: Exceeding the duty cycle ratings will cause the thermal overload
protection circuit to become energized and shut down the output until has cooled
to normal operating temperature
NOTICE£º
Due to variations that can occur in manufacture products, claimed performance, voltages, ratings, all
capacities, measurements, dimensions and weights quoted are approximate only. Achievable capacities and
ratings in use and operation will depend upon correct installation, use, applications, maintenance and service.
BOSS ARC 140¡¢ 160 Operating Manual
TIG
STICK
Continually exceeding the duty cycle ratings
can cause damage to the welding power source.
BOSS ARC 140
220/240V 50/60Hz 1ph
4.3KVA
6.0KVA
140A
10~140A
56/61V
60%
9.5kg
370×150×245
Table 3
- 9 -
BOSS ARC 160
220/240V 50/60Hz 1ph
4.8KVA
7.4kVA
160A
10~160A
56/61V
60%
12kg
420×160×265

Advertisement

Table of Contents
loading