3. Error code
DISPLAY
MECHA ERROR 01
No input of S3. The original position error of Disc Number.
MECHA ERROR 02
No input of S2. The turning direction error to counterclockwise.
MECHA ERROR 03
No input of S1. The turning direction error to clockwise.
MECHA ERROR 04
No input of main load sw.
MECHA ERROR 05
No input of main unload sw.
MECHA ERROR 06
No input of sub load sw.
MECHA ERROR 07
No input of sub unload sw.
MECHA ERROR 08
No backed up(AC power cord has disconnected).
S1-3: Mechanism address detector switch.
There are load and unload switches in the main pickup.
CD-4900M/DPF-J9030
CIRCUIT DESCRIPTION
ERROR CONTENTS
SENSOR PCB
S2
S3
S1
S1 DISC 1~9
S2 DISC 10~99
S3 DISC 100~200
7